Specification

1
2
3
4
5
4
6
7
1
2
3
4
5
6
7
1
2
3
4
5
6
7 8
9
6
Ideal applications for COMFORTBATT
®
insulation.
The higher density of ROCKWOOL COMFORTBATT
®
ensures a snug
friction t in the wall cavity. Note: A vapor retarder may be required
in the wall assembly, depending on the geographical location of the
building.
The COMFORTBATT
®
Residential Wall Assembly
(shown from outside to inside)
Cladding
Air Barrier
Sheathing
2” x 6” Wood Studs
5.5” COMFORTBATT
®
Vapor Retarder*
Gypsum
In addition to residential applications, ROCKWOOL COMFORTBATT
®
is ideal as a component of the BEDR
cavity wall system.
BEDR Wall Components
(shown from outside to inside)
Terra Cotta Cladding
1” Air Space (1/2” minimum)
1”-2” CAVITYROCK
®
MD Insulation (R4.2–R8.4)
or 2.5”–5” CAVITYROCK
®
DD (R10.75–R21.5)
Permeable Air Barrier
Exterior Gypsum Board
3.5” or 6” Steel Stud
3.5” or 6” COMFORTBATT
®
Insulation
Vapor Barrier*
5/8” Gypsum Board
When insulating attics, use two layers of COMFORTBATT
®
to achieve the
required R-value. The bottom layer should run parallel to the joists and the
top layer run in the opposite direction. For attics and cathedral ceilings,
only a single layer of COMFORTBATT
®
is required between the roof trusses.
The COMFORTBATT
®
Roof/Attic Assembly
(shown from outside to inside)
Shingles
Tar Paper
Sheathing
2” x 10” Roof Trusses
COMFORTBATT
®
(R30/R32)
Ceiling Joists
COMFORTBATT
®
(R22/R23 or R28/R30)
two layers running perpendicular
*Check with your local building code for approved vapor barrier/retarder information.