ROCKWOOL Safe'n'Sound Fire and Soundproofing Insulation

ROCKWOOL
4
Typical Assemblies for
ROCKWOOL Safe’n’Sound
®
Single stud interior wall
(Wood Studs – 16” On Center)
Using ROCKWOOL Safe’n’Sound
®
,
5/8” drywall (type x) and resilient
channels at 16” provides:
Fire Rating: 1 hour
Sound Transmission Class (STC): 45
ROCKWOOL Safe’n’Sound
®
Wall Components
(shown from outside to inside)
1. 5/8” Type X Gypsum
2. 3” Safe’n’Sound
®
3. Resilient Channel
4. 5/8” Type X Gypsum Board
Interior ceiling/oor
(2 x 10 Joists – 16” On Center)
Using ROCKWOOL Safe’n’Sound
®
,
5/8” drywall (type x) and resilient
channels at 24” provides:
Fire Rating: 30 minutes
Sound Transmission Class (STC): 50
ROCKWOOL Safe’n’Sound
®
Ceiling/Floor Components
(shown from top to bottom)
1. Plywood Floor
2. Air Space
3. 6” Safe’n’Sound
®
4. Resilient Channel
5. Gypsum Board
Top View
Side View
Because it doesn’t burn, Safe’n’Sound
®
can
delay the spread of re for added safety.