Specifications
7 ROCPOWER ‐ ROCWAVEusermanual
9.Sitewiringfault
LED
RedLEDindicatesLive&Neutrallinesare
improperlyconnectedorthereisHigh
Neutral‐Groundvoltage
10.Battery
Bad/Weak
LED
RedLEDindicateslowbatterypoweror
faultybatterybank
11.SelfTestLED
GreenLEDindicatessuccessfulself‐test
andnoabnormalconditionsorfaults
werefound
12.Outlet2LED
GreenLEDindicates2UPSOutletsare
enabledandreadytosupplyloads
13.Outlet1LED
GreenLEDindicates1UPSOutletis
enabledandreadytosupplyloads
7~11LEDs
(%Indicating
Bars)
a.DuringNormalMode:Pressandhold
for1sec.The7~11LEDswill
functionasLoadRateindicators
showing100%,75%,50%,25%or10%
ofUPScapacity.TheseLEDswillstop
illuminatingafter10sec.
b.DuringBatteryMode:Pressandhold
for1sec.The7~11LEDswill
functionasBatteryPowerindicators
showing100%,75%,50%,25%or10%
BatteryPowerremaining.TheseLEDs
willstopilluminatingafter10sec.