Parameter:
<Source> C1 | C2 | C3 | C4 | M1 | D0 | D1 | D2 | D3 | D4 | D5 | D6 | D7
*RST: C1
CURSor:COUPling <Coupling>
Couples the cursor lines so that the distance between the two lines remains the same
if one cursor is moved.
Parameter:
<Coupling> ON | OFF
*RST: OFF
CURSor:SCPLing
<ScaleCoupling>
If ON, the position of the cursor lines is adjusted if the vertical or horizontal scales are
changed. If OFF, the cursor lines remain on their position on the display if the scaling is
changed.
Parameter:
<ScaleCoupling> ON | OFF
*RST: OFF
CURSor:SCReen
Sets the cursors to a default position on the screen.
Verwendung:
Ereignis
CURSor:MEASurement<m>:TYPE <Type>
Sets the automatic measurements to be performed on the source waveform between
the cursor lines. The setting is only available if CURSor:FUNCtion is set to MEASure.
Suffix:
<m>
.
1..2
Defines the measurement index. Two simultaneous cursor mea-
surements can be performed.
Parameter:
<Type> PERiod | FREQuency | RTIMe | FTIMe | PPULse | NPULse |
PDCYcle | NDCYcle | MEAN | RMS | CRESt | STDDev |
MINimum | MAXimum | PKPK | BASelevel | TOPLevel |
AMPLitude | OVRShoot | PREShoot | AC | DC | ACDC |
PPCount | NPCount | RECount | FECount
See MEASurement<m>:TYPE auf Seite 338.
*RST: MINimum