User manual

Waveform Setup
R&S
®
Scope Rider RTH
59User Manual 1326.1578.02 ─ 04
"Equal"
If the pattern is true for the time "Pattern Width"
±
Δt (Tolerance), the
trigger occurs.
"Unequal"
If the pattern is true for a time shorter than "Pattern Width" - Δt OR
longer than "Pattern Width" + Δt, the trigger occurs.
"Inside"
If the pattern is true for a time between "Min Pattern Width" and "Max
Pattern Width", the trigger occurs.
"Outside"
If the pattern is true for a time shorter than "Min Pattern Width" OR
longer than "Max Pattern Width", the trigger occurs.
Remote command:
TRIGger:PATTern:WIDTh:RANGe on page 175
TRIGger:PATTern:TIMeout[:TIME] on page 175
TRIGger:PATTern:WIDTh[:WIDTh] on page 175
TRIGger:PATTern:WIDTh:DELTa on page 176
TRIGger:PATTern:WIDTh[:WIDTh] on page 175
TRIGger:PATTern:WIDTh:DELTa on page 176
2.5.7 State Trigger (R&S RTH-K19)
The state trigger verifies if the channel states match the defined pattern at the clock
edge. The trigger occurs if the logical combination of the input channels is true at the
crossing point of the selected clock edge and the trigger level.
SETUP key > "Trigger Type" = "State"
Description of settings
Figure 2-12: State Trigger
Clock Source
Selects the input channel of the clock signal.
Remote command:
TRIGger:STATe:CSOurce[:VALue] on page 177
Trigger