Datasheet

Version 08.00, March 2016
4 Rohde & Schwarz R&S
®
RTH1002, R&S
®
RTH1004 Scope Rider
Base unit
Vertical system
Input channels R&S
®
RTH1002 2 oscilloscope channels, 1 multimeter
R&S
®
RTH1004 4 oscilloscope channels
All inputs are floating and fully isolated in line with CAT IV 600 V, CAT III 1000 V safety
rating. See figure regarding isolation rating on page 13.
Input impedance 1 M ± 1 % || 12 pF ± 2 pF (meas.)
Analog bandwidth (–3 dB) R&S
®
RTH1002 and R&S
®
RTH1004 60 MHz
R&S
®
RTH1002 with -B221 option and
R&S
®
RTH1004 with -B241 option
100 MHz
R&S
®
RTH1002 with -B222 option and
R&S
®
RTH1004 with -B242 option
200 MHz
R&S
®
RTH1002 with -B223 option and
R&S
®
RTH1004 with -B243 option
350 MHz
1
R&S
®
RTH1002 with -B224 option and
R&S
®
RTH1004 with -B244 option
500 MHz
1
Measurement of analog bandwidth at input sensitivities 20 V/div is limited by input
voltage rating versus frequency, see figure “Input rating: Maximum signal voltage at
oscilloscope input” on page 13.
Lower frequency limit (–3 dB) at
AC coupling
< 8 Hz (meas.)
Bandwidth limits 1/2/5/10/20/50/100/200/500 kHz,
1/2/5/10/20/50 MHz
only with R&S
®
RTH-B222, -B242, -B223,
-B243, -B224, -B244 options
100 MHz
only with R&S
®
RTH-B223, -B243, -B224,
-B244 options
200 MHz
Rise time (calculated) R&S
®
RTH1002 and R&S
®
RTH1004 < 5.8 ns
R&S
®
RTH1002 with -B221 option and
R&S
®
RTH1004 with -B241 option
< 3.5 ns
R&S
®
RTH1002 with -B222 option and
R&S
®
RTH1004 with -B242 option
< 1.75 ns
R&S
®
RTH1002 with -B223 option and
R&S
®
RTH1004 with -B243 option
< 1 ns
2
R&S
®
RTH1002 with -B224 option and
R&S
®
RTH1004 with -B244 option
< 700 ps
2
ADC resolution 10 bit
Vertical resolution of overall system 9 bit
DC gain accuracy offset and position set to zero, after self-alignment
input sensitivity > 5 mV/div ±1.5 %
input sensitivity > 2 mV/div to 5 mV/div ±2 %
input sensitivity 2 mV/div ±2.5 %
Input coupling DC, AC
Input sensitivity in steps of 1, 2, 4, 5 in each decade 2 mV/div to 100 V/div
Maximum input voltage at BNC inputs CAT IV 300 V (RMS), 424 V (peak),
derates at 20 dB/decade to 5 V (RMS)
above 500 kHz (see figure “Input rating:
Maximum signal voltage at oscilloscope
input” on page 13)
with R&S
®
RT-ZI10 or R&S
®
RT-ZI11 probe CAT IV 600 V, CAT III 1000 V,
derating in line with probe specification
Position range ±4 div
Offset range input sensitivity
40 V/div 0
1 V/div to 20 V/div ±200 V
500 mV/div ±4 V
Offset accuracy after self-alignment ±( 0.5 % × |net offset| +
0.1 div × input sensitivity + 1.5 mV )
(net offset = offset – (position × input
sensitivity))
1
200 MHz (meas.) for input sensitivities 20 V/div.
2
< 1.75 ns (calculated) for input sensitivities 20 V/div.