Datasheet

Attenuation ratio: 10:1
Bandwidth: 250 MHz
Rise time: <1.4 ns
Input impedance: 10 MΩ II 10 pF
Max. Voltage: 600 V (DC + peak AC)
LF compensation: 1 Trimmer
RF compensation: 2 Trimmer
Cable length: 1.2 m
Measuring category: CAT I
HZ52 Probe 10:1
Attenuation ratio: 1:1
Switchable: 10:1
Bandwidth: 10/100 MHz
Rise time : <35/3.5 ns
Input impedance: 1/10 MΩ II 82/12 pF
Max. Voltage: (10:1) 600 V (DC + peak AC)
LF compensation: 1 Trimmer at 10:1
RF compensation: 2 Trimmer at 10:1
Cable length: 1.2 m
Measuring category: CAT I
HZ154 Probe 1:1/10:1
Attenuation ratio: 10:1
Bandwidth: 500 MHz
Rise time: <700 ps
Input impedance: 10 MΩ II 9.5 pF
Max. Voltage: 400 V (DC + peak AC)
LF compensation: 1 Trimmer
RF compensation: 2 Trimmer
Cable length: 1.3 m
Probe factor identification: automatically after connection
Measuring category: CAT I
HZ355 Probe 10:1
Attenuation ratio: 10:1
Bandwidth: 350 MHz
Rise time: <1.0 ns
Input impedance: 10 MΩ II 12 pF
Max. Voltage: 400 V (DC + peak AC)
LF compensation: 1 Trimmer
RF compensation: 2 Trimmer
Cable length: 1.2 m
Probe factor identification: automatically after connection
Measuring category: CAT I
HZ350 Probe 10:1
Attenuation ratio: 10:1
Bandwidth: 150 MHz
Rise time: <2.4 ns
Input impedance: 10 MΩ II 12 pF
Max. Voltage: 600 V (DC + peak AC)
LF compensation: 1 Trimmer
RF compensation: 1 Trimmer
Cable length: 1.2 m
Measuring category: CAT I
HZ51 Probe 10:1