® R&S HMP Series Power Supplies Getting Started (;ÜÑé2) Getting Started 1178.6791.
This manual applies to the following models and options of the R&S®HMP series: ● R&S®HMP2020 Two-Channel Power Supply (3629.6718.02) ● R&S®HMP2030 Three-Channel Power Supply (3629.6718.03) ● R&S®HMP4030 Three-Channel Power Supply (3629.6776.03) ● R&S®HMP4030 Four-Channel Power Supply (3629.6776.04) This manual describes firmware version FW V2.61 and later for the instruments of the of the R&S®HMP Series. © 2018 Rohde & Schwarz GmbH & Co. KG Mühldorfstr.
R&S®HMP Series Contents Contents 1 Documentation Overview......................................................5 1.1 Getting Started Manual.........................................................................5 1.2 User Manual...........................................................................................5 1.3 Basic Safety Instructions..................................................................... 5 1.4 Brochure and Specifications........................................................
R&S®HMP Series Getting Started 1178.6791.
R&S®HMP Series Documentation Overview Brochure and Specifications 1 Documentation Overview This section provides an overview of the R&S HMP user documentation. Unless specified otherwise, you find the documents on the R&S HMP product page at: www.rohde-schwarz.com/manual/hmp 1.1 Getting Started Manual Introduces the R&S HMP and describes how to set up and start working with the product. Includes basic operations, and general information, e.g. safety instructions, etc.
R&S®HMP Series Documentation Overview Remote Control Drivers 1.5 Release Notes The release notes list new features, improvements and known issues of the current firmware version, and describe the firmware installation. The release notes are part of the download up-to-date firmware at www.rohdeschwarz.com/firmware/hmp. 1.6 Remote Control Drivers The instrument drivers enable remote control via the corresponding interfaces.
R&S®HMP Series 2 For Your Safety For Your Safety The instruments of the R&S HMP series are designated for use in industrial, administrative, and laboratory environments, and residential, business, commercial and small business areas. The instruments comply with protection class II. Use an R&S HMP only for its designated purpose. Observe the safety and usage instructions documented in the user manual, and operating conditions and performance limits stated in the data sheet.
R&S®HMP Series 3 Key Features Key Features The R&S HMP Series power supplies sets standards in performance and usability. Outstanding key features are: ● High output power within a minimum space, high efficiency and low residual ripple. ● High programming and readback resolution for applications with the highest demands. ● Realtime voltage, current and power values. ● EasyArb function for programming voltage and current processes directly on the instrument.
R&S®HMP Series Preparing for Use Putting into Operation 4 Preparing for Use 4.1 Putting into Operation This section describes the basic steps to be taken when setting up the R&S HMP for the first time. 4.1.1 Safety This instrument is built in compliance with DIN EN 61010-1 (VDE 0411 part 1), safety regulations for electrical measuring instruments, control units and Laboratory equipment. It has been tested and shipped from the plant in safe condition.
R&S®HMP Series Preparing for Use Putting into Operation Risk of injury due to disregarding safety information Observe the information on appropriate operating conditions provided in the data sheet to prevent personal injury or damage to the instrument. Read and observe the basic safety instructions provided with the instrument, in addition to the safety instructions in the following sections. In particular: ● Do not open the instrument casing.
R&S®HMP Series Preparing for Use Putting into Operation Risk of instrument damage during operation An unsuitable operating site or test setup can damage the instrument and connected devices. Ensure the following operating conditions before you switch on the instrument: ● Make sure that the nominal voltage setting on the product matches the nominal voltage of the AC supply network. If you have a different line voltage, it can be necessary that you have to change the power fuse of the product.
R&S®HMP Series Preparing for Use Putting into Operation ● Before each measurement, check the instrument for proper operation using a known signal source or sample. ● Signal levels at the input connectors are all within the specified ranges. ● Signal outputs are correctly connected and are not overloaded. If it is assumed that a safe operation is no longer possible, the instrument must be shut down and secured against any unintended operation.
R&S®HMP Series Preparing for Use Putting into Operation 4.1.2 Unpacking and Checking the Instrument To remove the instrument from its packaging and check the equipment for completeness, proceed as follows: ● Check the package for damage. ● Carefully unpack the instrument and the accessories. ● Check the package contents for completeness using the delivery list see (Chapter 4.1.3, "Delivery List", on page 13) and package contents.
R&S®HMP Series Preparing for Use Putting into Operation 4.1.4 Placing or Mounting the Instrument The R&S HMP is designed for use under both, industry and laboratory conditions, either on a bench top or in a rack. Bench Top Operation If the R&S HMP is operated on a bench top, the surface must be flat. You can place the instrument horizontally, or in a slope position by unfolding the front feet.
R&S®HMP Series Preparing for Use Putting into Operation Risk of injury when stacking instruments A stack of instruments can tilt over and cause injury if not stacked correctly. Furthermore, the instruments at the bottom of the stack can be damaged due to the load imposed by the instruments on top. Observe the following instructions when stacking instruments: ● Never stack more than three instruments. If you need to stack more than three instruments, install them in a rack.
R&S®HMP Series Preparing for Use Putting into Operation 2. Remove the feet. Tip: Save the feet with the screws if you want to operate the R&S HMP as bench top later. Risk of instrument damage due to insufficient airflow in a rack If the instrument is run with insufficient airflow for a longer period, the instrument overheats, which can disturb the operation or turn off the R&S HMP.
R&S®HMP Series Preparing for Use Putting into Operation The instrument must only be connected to an outlet that has a ground contact, according to the specifications for safety class EN 61010. Replacing the Fuses The instrument has main power fuses, which are located on the rear panel of the unit. Depending on the line voltage setting, the fuses of the correct type must be installed. Risk of electric shock The fuses are part of the main power supply.
R&S®HMP Series Preparing for Use Setting Up a Network (LAN) Connection 4. Exchange the fuses. 5. Note: The protruding contact springs must not be deformed, therefore: Align the fuse holder with the guide bar facing the socket. 6. Carefully slide the fuse holder against the spring pressure into the slot until both plastic locks latch. 4.1.
R&S®HMP Series Preparing for Use Setting Up a Network (LAN) Connection This section describes how to set up and configure the LAN interface. For remote control via the alternative interfaces, refer to the user manual of the R&S HMP. Risk of network failure Consult your network administrator before performing the following tasks: ● Connecting the instrument to the network ● Configuring the network ● Changing IP addresses ● Exchanging hardware Errors can affect the entire network.
R&S®HMP Series Preparing for Use Setting Up a Network (LAN) Connection To assign the IP address manually on the instrument To assign the IP address, first select the interface. In addition, check if DHCP is not active. Otherwise, you cannot edit the IP address. 1. To disable DHCP, perform the following steps: Tip: Skip these steps, if DHCP is not supported. a) b) c) d) Press the Menu key. Select "Interface > Interface Settings > Port Settings /DHCP". Select "DHCP: > OFF". Return with the left arrow key.
R&S®HMP Series Preparing for Use Setting Up a Network (LAN) Connection Checking the LAN connection To verify the connection, you can use the ping command. ► In the command prompt on the remote PC, enter ping When the connection is working, the command returns the reply from the instrument. Getting Started 1178.6791.
R&S®HMP Series Instrument Tour Front Panel Views of the R&S HMP2030 and the R&S HMP2020 5 Instrument Tour The following sections explain the control elements and the connectors of the R&S HMP Series instruments by their front and rear views. ● The control elements on the front panel illuminate when you turn them on. In addition, the instrument illuminates keys for navigating or entering settings automatically if necessary. ● The channel keys also change their color.
R&S®HMP Series Instrument Tour Front Panel Views of the R&S HMP4040 and the R&S HMP4030 Figure 5-1: Front view of the R&S HMP2030 1 = Power key: Turning the instrument on and off 2 = Display (LCD): Parameter display 3 = Arrow keys and Rotary knob: Navigating on the display, setting and confirming the parameters 4 = Ch1, Ch2, Ch3 keys: Selecting Channels 5 = Output key: Turning on or off the selected channels 6 = Voltage key: Setting the output voltage 7 = Track key: Activating the tracking function 8 = S
R&S®HMP Series Instrument Tour Rear Panel Views of the R&S HMP2030 and the R&S HMP2020 Figure 5-2: Front view of the R&S HMP4040 1 = Power key: Turning the instrument on and off 2 = Display (LCD): Parameter display 3 = Arrow keys and Rotary knob: Navigating on the display, setting and confirming the parameters 4 = Ch1, Ch2, Ch3, Ch4 keys: Selecting Channels 5 = Output key: Turning on or off the selected channels 6 = Keypad keys: Setting the nominal values 7 = Voltage key: Setting the output voltage 8 = T
R&S®HMP Series Instrument Tour Rear Panel Views of the R&S HMP4030 and the R&S HMP4040 Figure 5-3: Rear view of the HMP20x0 series 17 = Interface: Ethernet / USB dual interface R&S HO732 (default for all instruments of the R&S HMP series) 18 = Output connector: Rear panel outputs for integration into rack systems (2 to 3 channels) 19 = Voltage selector: Selecting the line voltage 115 V or 230 V 20 = Power supply connector: IEC socket and fuse holder 5.
R&S®HMP Series Instrument Tour Rear Panel Views of the R&S HMP4030 and the R&S HMP4040 19 = Interface: Ethernet / USB dual interface R&S HO732 (default for all instruments of the R&S HMP series) 20 = Output connectors: Rear panel outputs for integration into rack systems (3 to 4 channels, depending on the R&S HMP40x0 model) 21 = Power supply connector: IEC socket and fuse holder 22 = Voltage selector: Selecting the line voltage 115 V or 230 V Risk of interference by electrostatic discharge When the front
R&S®HMP Series 6 Trying Out the Instrument Trying Out the Instrument This chapter describes the first steps with the R&S HMP. It shows a simple configuration for providing the power at the output. For basics on operating the instrument, see Chapter 7, "Instrument Control", on page 30. The complete description of the functionality and its usage is given in the R&S HMP user manual. Prerequisites ● The instrument is set up, connected to the mains, and started up as described in Chapter 4.1.
R&S®HMP Series Trying Out the Instrument Selecting the output voltage 1. Press the Voltage key. The Voltage key and the arrow keys are illuminated, indicating that they are active. 2. Press the channel key, e.g. Ch1. Activates the voltage setting. The Ch1 key illuminates blue. 3. Set the output voltage value by turning the rotary knob. The R&S HMP applies the setting immediately. 4. To terminate the setting, press the Voltage key. The Ch1 key illuminates green again.
R&S®HMP Series Trying Out the Instrument The R&S HMP immediately applies the setting and indicates the activated fuse in the display. After the fallback time has elapsed, the instrument exits the setting mode. See Chapter "Instrument Functions > General Functions > Key Fallback Time" in the user manual. 3. Repeat step 1 and step 2 to disable the fuse function. Activating the output You can turn on and off the output voltages regardless of the operating mode the instrument is in. 1. Press the Ch1 key. 2.
R&S®HMP Series Instrument Control Means of Manual Interaction 7 Instrument Control This chapter provides an overview on how to work with the R&S HMP. It covers the following topics: ● Ways to Operate the Instrument..................................................................... 30 ● Means of Manual Interaction...........................................................................30 ● Remote Control...............................................................................................
R&S®HMP Series Instrument Control Means of Manual Interaction Understanding the display information Brief overview of the displayed elements: ● Home screen: Displays the channel parameters. ● Menus: Lists functions leading to the setting dialogs. ● Dialogs: Provide the settings of the specific functions. Illuminated keys The illuminated front panel keys provide access to the instrument settings and to activate functions and operating modes.
R&S®HMP Series Instrument Control Means of Manual Interaction – Increments (clockwise direction) or decrements (counterclockwise direction) the instrument parameter at a defined step size in the case of a numeric entry – Acts like the Enter key, when it is pressed ● Arrow keys – Move the selection up and down, or forward and backward, e.g.
R&S®HMP Series Instrument Control Remote Control Throughout the user documentation, the instructions for configuring settings use the rotary knob and arrow keys. The alternative operating methods are only noted here. 7.3 Remote Control In addition to operating the R&S HMP directly on the instrument, it is also possible to operate and control it from a remote PC.
R&S®HMP Series Index Index A L Activating the fuse ................................... 28 Activating the output ................................ 29 Application examples ................................ 6 Application notes ....................................... 6 LAN connection Not working ......................................... 19 B Bench top operation ................................ 14 Brochure .................................................... 5 Brochures .....................................
R&S®HMP Series Index Remote connection Not working ......................................... 19 Remote control .................................. 30, 33 Drivers .................................................. 6 Interfaces ............................................ 33 S Safety .................................................... 7, 9 Safety instructions ..................................... 5 Saving instrument settings ...................... 29 SCPI programmers manual .......................