Product Info

Digital Reprogrammable Software Radios M3SR 9
Plug-in option
Dimensions
Transceiver/transmitter (DC) 19" plug-in, 3 HU
Transceiver/transmitter set (AC/DC) 19" plug-in, 3 HU + 1 HU (AC power
supply)
Receiver/multiple receiver (AC/DC) 19" plug-in, 3 HU
Additional space for rear cabling 200 mm recommended
Weight
Receiver approx. 14 kg
Transceiver approx. 16.5 kg
EPM transceiver incl. guard receiver approx.17.5 kg
External Universal Power Supply
IN4000A
5.7 kg
Logistics
MTTR on module level 15 min typ.
Important note: All adjustments, settings and configurations stated above can
be performed locally or remotely via software.
Guard Receiver ET4400G
Guard (distress) frequencies 121.5 MHz and 243 MHz in parallel at
the same time
Input signal protection +21 dBm
Sensitivity (with AM (m = 0.3),
121.5/243 MHz)
ITU-T S+N/N = 10 dB
–101 dBm
Image and spurious rejection 80 dB
Selectivity (IF bandwidth) 30 kHz/6 dB, 75 kHz/60 dB
AM internal noise level
(with input signal –47 dBm,
f
m
= 1 kHz, m = 0.8) (S+N)/N = 40 dB (modulated-to-
unmodulated), weighted to ITU-T
Note: If a guard receiver with common main receiver antenna is installed in an
M3SR, the sensitivity of the main receiver is reduced by 4 dB.
General data
Operating temperature range –20°C to +55°C
Storage temperature range –40°C to +70°C
Humidity 95% at +45°C to MIL-STD-810D
method 507.2 and DIN IEC68-2-30
without condensation and
50% at –5/+20°C to DIN IEC68-2-14
Dust and water protection
Control unit
Radio
IP 54
IP 20
Fungus protected to MIL-STD-810C method
508.2
Permissible altitude
Permanent operation
5 min operation
Transport
5000 m asl
10000 m asl
10000 m asl
Vibration 5 Hz to 55 Hz, 0.4 mm double
amplitude, test period: 30 min to
DIN IEC68-2-14, MIL-STD-167-1 type 1,
STANAG4138
Shock 45 Hz to 2000 Hz, 40 g, 3 shocks in
two of three axes to DIN IEC68-2-27,
MIL-STD-810D method 516.3
EMI/EMC EN300 339
MIL-STD-461E: CE101, CE102, CE106,
CS101, CS114, RE101, RE102, RS101
(maximally achieved test field strength
160 dBpT), RS-103 (2 MHz to 1 GHz,
test field strength 10 V/m)
Transients and spikes (AC supply) STANAG1008 edition 8 and
MIL-STD-1399 sec.103 type 1
Electrical safety Directive 72/23/EEC (CE mark), IEC950,
VDE0804, VDE0805, VDE0866,
EN60950
Cooling sensor-controlled forced-air cooling by
integrated fans, air flow direction from
front to rear side; if there is a front
door, it should have sufficient air inlets
Power supply
DC operation
AC operation
Receiver
Transmitter, transceiver
AC/DC operation
Power consumption
(example: VHF/UHF transceiver with
CCP, EPM, guard RX)
28 V nominal, 19 V to 31 V with some
degradations (acc. to Directives
89/336/EEC and 72/23/EEC)
90 V to 264 V, 47 Hz to 63 Hz
90 V to 264 V, 47 Hz to 63 Hz; 110 V at
400 Hz to 440 Hz (with external
IN4000A)
automatic switchover; priority to AC
depending on configuration and DC/
AC supply
approx. 80 W (receive mode, DC)
approx. 380 W/505 VA for VHF/UHF
30 W AM/100 W FM (transmit mode,
AC/DC)
Certified Environmental System
ISO 14001
REG. NO 1954
Certified Quality System
ISO 9001
DQS REG. NO 1954