User Manual

065 75$16&(,9(5 ; $ ; $
Operator’s Manual Use under Special Conditions
6076.0822.12.01 – 3.47 –
 0HQX3DJH$),3$5$0(7(56$XGLR)UHTXHQF\,QWHUIDFH
In this menu the parameters of the Audio Frequency Interface are displayed and edited (page
1 of 2). The default parameters have been selected to allow optimum performance. If, however,
changes were made at some point and the operator then wants to re-establish the default set-
tings (see Appendix A1), he only needs to press the Default softkey in Menu 400 (RADIO
MAINTENANCE).
Starting point: Menu 510 (RADIO MODULES)
+ Press softkey (7) and select module AUDIO INTERFACE by using the tuning
knob.
+ Press softkey (3) and the following display appears:
No. Control Action Notes
2 Press softkey
CODEC.
Select setting.
Selection of interface for level setting
The Rx level and Tx level are both as-
signed to the selected NB or WB channel.
3 Press softkey
TX ALC.
Enter value.
Entry of the TX ALC ATTACK time for
transmitter AF signals in the range from
10 ms to 100 ms, 30 ms is recommended.
1RWH
&XVWRPHUVSHFLILFVHWWLQJVFDQEHFRQILJXUHG
DVUHTXLUHG
4 Press softkey
ALC DECAY.
Enter value.
Entry of the ALC DECAY time for trans-
mitter AF signals in the range from
100 ms to 2 000 ms, 300 ms is recom-
mended.
1RWH
&XVWRPHUVSHFLILFVHWWLQJVFDQEHFRQILJXUHG
DVUHTXLUHG
page 2


0HQX