6076.0822.12.01 – 4.11 –
0205 PS MAIN VLT LOW W DC power supply warning:
Main voltage (28 VDC) low
CBIT message:
Send radio to depot.
Frequent event:
Check configuration (Menu 511, func-
tion PWR SUP). Switch off and check
external power supply, cables and
connectors at X31. If this fails to elimi-
nate the fault, send the radio to depot.
Single event:
Check configuration (Menu 511, func-
tion PWR SUP). Switch off and check
external power supply, cables and
connectors at X31.
0206 PS BATT VLT LOW W DC power supply warning:
Battery voltage low
CBIT message:
Send radio to depot.
Frequent event:
Check configuration (Menu 511, func-
tion PWR SUP). Switch off and check
external power supply, cables and
connectors at X31. If this fails to elimi-
nate the fault, send the radio to depot.
Single event:
Check configuration (Menu 511, func-
tion PWR SUP). Switch off and check
external power supply, cables and
connectors at X31.
0207 PS VLT LW VLIM W DC power supply warning:
VLIM voltage low
CBIT message or frequent event:
Send radio to depot.
Single event:
no action
0208 PS VLT EXT SW W DC power supply warning:
Voltage for external switch
low
CBIT message or frequent event:
Send radio to depot.
Single event:
no action
0209 PS 28V LT AMP LOW DC W DC power supply warning:
28 VDC for left amplifier
low
CBIT message or frequent event:
Send radio to depot.
Single event:
no action
0210 PS 28V RT AMP LOW DC W DC power supply warning:
28 VDC for right amplifier
low
CBIT message or frequent event:
Send radio to depot.
Single event:
no action
0211 PS 28V DRV AMP LOW W DC power supply warning:
28 VDC for driver amplifier
low
CBIT message or frequent event:
Send radio to depot.
Single event:
no action
0212 PS VLT PAX LW VLIM W DC power supply warning
Voltage power amplifier
below limit
CBIT message or frequent event:
Send radio to depot.
Single event:
no action
0213 PS OVERTEMP W DC power supply warning:
Overtemperature in power
supply unit
CBIT message or frequent event:
Check airflow of fans and ambient
temperature. If this fails to eliminate
the fault, send radio to depot.
Single event:
Check airflow of fans and ambient
temperature.
Code Message Level Notes Action
(CBIT message,