Operating instructions

SENSe:FMEasurement Subsystem R&S ESCI
1166.6004.12 6.166 E-1
SENSe:FMEasurement Subsystem
This subsytsem control the parameters of final measurement in the receiver.
COMMAND PARAMETER UNIT COMMENT
[SENSe<1|2>]
:FMEasurement
:THReshold
[:STATe]
:NBBB
[:STATe]
:LEVel
:AUTO
:LISN
[:TYPE]
:PHASe
:PEARth
:TIME
<Boolean>
<Boolean>
<numeric_value>
<Boolean>
TWOPhase | FOURphase | OFF
L1 | L2 | L3 | N, L1 | L2 | L3 | N ..
GROunded | FLOating, GROunded |
FLOating ..
<numeric_value>
--
--
DB
--
--
--
--
S
:[SENSe<1|2>:]FMEasurement:THReshold[:STATe] ON | OFF
Example: "FME:THR ON "
Characteristics: *RST value: OFF
SCPI: device-specific
Mode: R
:[SENSe<1|2>:]FMEasurement:NBBB[:STATe] ON | OFF <numeric_value>:
Example: "FME:NBBB ON"
Characteristics: *RST value: OFF
SCPI: device-specific
Mode: R
:[SENSe<1|2>:]FMEasurement:NBBB:LEVel <numeric_value>:
This command enters the decision threshold to be used by the analyzer to discriminate between
broadband and narrowband interference.
Example: "FME:NBBB:LEV 6 DB "
Characteristics: *RST value: 6 dB
SCPI: device-specific
Mode: R
:[SENSe<1|2>:]FMEasurement:AUTO ON | OFF
This command switches between automatic and interactive final measurement.
Example: "FME:AUTO ON"
Characteristics: *RST value: ON
SCPI: device-specific
Mode: R