Operating instructions

R&S ESCI CALCulate:MARKer Subsystem
1166.6004.12 6.55 E-1
CALCulate<1|2>:MARKer<1 to 4>:FUNCtion:CSTep
This command sets the step width of the receiver or center frequency in the selected measurement
window to the X value of the current marker. If marker 2, 3 or 4 is selected and used as delta
marker, it is switched to the marker mode.
Example: "CALC2:MARK2:FUNC:CST" 'Sets the receiver frequency to the same value
'as the frequency of marker 2.
Characteristics: *RST value: -
SCPI: device-specific
Mode: A-F
This command is an event and therefore has no *RST value and no query.
CALCulate<1|2>:MARKer<1 to 4>:FUNCtion:REFerence
This command sets the reference level in the selected measurement window to the power measured
by the indicated marker. If marker 2, 3 or 4 is selected and used as delta marker, it is switched to
marker mode.
Example: "CALC:MARK2:FUNC:REF" 'Sets the reference level of screen A to the the
'level of marker 2.
Characteristics: *RST value: -
SCPI: device-specific
Mode: A