User Manual

Instrument Tour
R&S
®
FPL1000
47Getting Started 1323.1602.02 ─ 03
The DC power supply (option R&S FPL1-B30) can be connected alternatively to
the AC power supply. DC power supplies from +12 V to +24 V and from 13 A to
6.5 A can be used. The connector is supplied with the accessories and is connec-
ted according to the following diagram:
Pin Description
1 2
3
1 Plus
2 Ground
3 Not used
Risk of electric shock!
If external power supply units for supplying safety extra-low DC voltage
(SELV) to the instrument are used, the requirements for reinforced/double
insulation in accordance with DIN/EN/IEC 61010 (UL 3111, CSA C22.2 No.
1010.1) or DIN/EN/IEC 60950 (UL 1950, CSA C22.2 No. 950) must be met.
Current limitation must be provided in accordance with DIN EN 61010-1
Appendix F2.1.
Otherwise there is a risk of electric shock.
4.2.2 AC Power Supply Connection and Main Power Switch
An AC power supply connector and main power switch are located in a unit on
the rear panel of the instrument.
Main power switch function:
Position 1: The instrument is in operation.
Position O: The entire instrument is disconnected from the AC power supply.
For details, refer to Chapter 3.1.4, "Connecting the AC Power", on page 16.
Rear Panel View