This measurement is not available in zero span.
Configuring search limits for OBW measurement
The OBW measurement uses the same search limits as defined for marker search
(see "Search Limits" on page 356). However, only the left and right limits are consid-
ered.
The remote commands required to perform these tasks are described in Chap-
ter 11.6.6, "Measuring the Occupied Bandwidth", on page 657.
% Power Bandwidth....................................................................................................156
Channel Bandwidth.....................................................................................................157
Adjust Settings............................................................................................................ 157
Search Limits (Left / Right)..........................................................................................157
Deactivating All Search Limits.....................................................................................157
% Power Bandwidth
Defines the percentage of total power in the displayed frequency range which defines
the occupied bandwidth. Values from 10 % to 99.9 % are allowed.
Remote command:
[SENSe:]POWer:BANDwidth on page 658