205User Manual 1178.3370.02 ─ 09
Abs Limit Start/ Abs Limit Stop....................................................................................207
Insert before Range/ Insert after Range......................................................................207
Delete Range.............................................................................................................. 207
Range Start / Range Stop
Sets the start frequency/stop frequency of the selected range.
You can define a span that is smaller than the overall span of the ranges. In this case,
the measurement includes only the ranges that lie within the defined span and have a
minimum span of 20 Hz.
Remote command:
[SENSe:]LIST:RANGe<ri>[:FREQuency]:STARt on page 691
[SENSe:]LIST:RANGe<ri>[:FREQuency]:STOP on page 692
Filter Type
Sets the filter type for this range.
For details on filter types, see Chapter 7.6.1.6, "Which Data May Pass: Filter Types",
on page 320.
Remote command:
[SENSe:]LIST:RANGe<ri>:FILTer:TYPE on page 692
RBW
Sets the RBW value for this range.
For details on the RBW, see Chapter 7.6.1.1, "Separating Signals by Selecting an
Appropriate Resolution Bandwidth", on page 317.
Remote command:
[SENSe:]LIST:RANGe<ri>:BANDwidth:RESolution on page 689
VBW
Sets the VBW value for this range.
For details on the VBW, see Chapter 7.6.1.2, "Smoothing the Trace Using the Video
Bandwidth", on page 318.
Remote command:
[SENSe:]LIST:RANGe<ri>:BANDwidth:VIDeo on page 690
Sweep Time Mode
Activates or deactivates the auto mode for the sweep time.
For details on the sweep time mode, see Chapter 7.6.1.7, "How Long the Data is Mea-
sured: Sweep Time", on page 320
Remote command:
[SENSe:]LIST:RANGe<ri>:SWEep:TIME:AUTO on page 696
Sweep Time
Sets the sweep time value for the range.
For details on the sweep time, see Chapter 7.6.1.7, "How Long the Data is Measured:
Sweep Time", on page 320
Measurements and Results