User Manual
The Spectrum Application (RF Measurements)
R&S
®
FPL1000
359User Manual 1178.3370.02 ─ 09
"Up"
Determines the next maximum/minimum above the current peak (in
more recent frames).
"Absolute"
Determines the next maximum/minimum above or below the current
peak (in all frames).
"Down"
Determines the next maximum/minimum below the current peak (in
older frames).
Remote command:
CALCulate<n>:MARKer<m>:SPECtrogram:Y:MAXimum:ABOVe on page 861
CALCulate<n>:DELTamarker<m>:SPECtrogram:Y:MAXimum:ABOVe
on page 865
CALCulate<n>:MARKer<m>:SPECtrogram:Y:MAXimum:BELow on page 861
CALCulate<n>:DELTamarker<m>:SPECtrogram:Y:MAXimum:BELow
on page 866
CALCulate<n>:MARKer<m>:SPECtrogram:Y:MAXimum:NEXT on page 861
CALCulate<n>:DELTamarker<m>:SPECtrogram:Y:MAXimum:NEXT on page 866
CALCulate<n>:MARKer<m>:SPECtrogram:Y:MINimum:ABOVe on page 862
CALCulate<n>:DELTamarker<m>:SPECtrogram:Y:MINimum:ABOVe
on page 867
CALCulate<n>:MARKer<m>:SPECtrogram:Y:MINimum:BELow on page 862
CALCulate<n>:DELTamarker<m>:SPECtrogram:Y:MINimum:BELow
on page 867
CALCulate<n>:MARKer<m>:SPECtrogram:Y:MINimum:NEXT on page 863
CALCulate<n>:DELTamarker<m>:SPECtrogram:Y:MINimum:NEXT on page 867
Marker Search Type
Defines the type of search to be performed in the spectrogram.
"X-Search"
Searches only within the currently selected frame.
"Y-Search"
Searches within all frames but only at the current frequency position.
"XY-Search"
Searches in all frames at all positions.
Remote command:
Defined by the search function, see Chapter 11.8.8.6, "Marker Search (Spectro-
grams)", on page 858
Marker Search Area
Defines which frames the search is performed in.
"Visible"
Only the visible frames are searched.
"Memory"
All frames stored in the memory are searched.
Remote command:
CALCulate<n>:MARKer<m>:SPECtrogram:SARea on page 860
CALCulate<n>:DELTamarker<m>:SPECtrogram:SARea on page 865
Exclude LO
If activated, restricts the frequency range for the marker search functions.
Marker Usage