User Manual

Remote Commands
R&S
®
FPL1000
634User Manual 1178.3370.02 ─ 09
Parameters:
<TraceNumber> Range: 1 to 6
*RST: 1
Example:
POW:TRAC 2
Assigns the measurement to trace 2.
Manual operation: See "Selected Trace" on page 137
11.6.3 Measuring Compression Points
All remote control commands specific to compression point measurements are descri-
bed here.
Configuring the Compression Point Measurement............................................... 634
Programming Example: Measuring Compression Points......................................638
11.6.3.1 Configuring the Compression Point Measurement
The following commands are required to configure compression point measurements
using an internal tracking generator.
For details see Chapter 7.2.3, "Power Sweep Measurements", on page 119.
For a programming example using remote commands, see Chapter 11.6.3.2, "Pro-
gramming Example: Measuring Compression Points", on page 638.
Useful commands for compression point measurements described elsewhere:
"Power Sweep Commands" on page 805
DISPlay[:WINDow<n>]:TRACe<t>:Y[:SCALe]:RPOSition on page 780
Remote commands exclusive to compression point measurements:
CONFigure:CMEasurement:REFerence:VALue.................................................................634
CONFigure:CMEasurement:REFerence[:MODE]...............................................................635
CONFigure:CMEasurement:RESult:CVALue.....................................................................635
CONFigure:CMEasurement:RESult:P1DB[:STAT]..............................................................635
CONFigure:CMEasurement:RESult:P3DB[:STAT]..............................................................636
CONFigure:CMEasurement:RESult:PNDB[:STAT]............................................................. 636
CONFigure:CMEasurement[:STATe].................................................................................637
FETCh:CMEasurement:P1DB[:RESult]?...........................................................................637
FETCh:CMEasurement:P3DB[:RESult]?...........................................................................637
FETCh:CMEasurement:PNDB[:RESult]?.......................................................................... 637
CONFigure:CMEasurement:REFerence:VALue <ReferenceValue>
Defines the reference value used to calculate the compression point for CONFigure:
CMEasurement:REFerence[:MODE] MANual.
Parameters:
<ReferenceValue> Default unit: DBM
Configuring and Performing Measurements