11.6.8.2 Configuring a Sweep List
The following commands configure the sweep list for spurious emission measure-
ments.
The sweep list cannot be configured using remote commands during an on-going
sweep operation.
Useful commands for configuring the sweep described elsewhere:
[SENSe:]SWEep:MODE on page 661
Remote commands exclusive to spurious measurements:
[SENSe:]LIST:RANGe<ri>:BANDwidth:RESolution............................................................ 689
[SENSe:]LIST:RANGe<ri>:BANDwidth:VIDeo................................................................... 690
[SENSe:]LIST:RANGe<ri>:BREak....................................................................................690
[SENSe:]LIST:RANGe<ri>:COUNt?..................................................................................690
[SENSe:]LIST:RANGe<ri>:DELete................................................................................... 691
[SENSe:]LIST:RANGe<ri>:DETector.................................................................................691
[SENSe:]LIST:RANGe<ri>[:FREQuency]:STARt................................................................ 691
[SENSe:]LIST:RANGe<ri>[:FREQuency]:STOP.................................................................692
[SENSe:]LIST:RANGe<ri>:FILTer:TYPE............................................................................692
[SENSe:]LIST:RANGe<ri>:INPut:ATTenuation...................................................................693
[SENSe:]LIST:RANGe<ri>:INPut:ATTenuation:AUTO.........................................................693
[SENSe:]LIST:RANGe<ri>:INPut:GAIN:STATe...................................................................693
[SENSe:]LIST:RANGe<ri>:INPut:GAIN[:VALue].................................................................694
[SENSe:]LIST:RANGe<ri>:LIMit:STARt.............................................................................694
[SENSe:]LIST:RANGe<ri>:LIMit:STATe.............................................................................694
[SENSe:]LIST:RANGe<ri>:LIMit:STOP............................................................................. 694
[SENSe:]LIST:RANGe<ri>:POINts[:VALue]....................................................................... 695
[SENSe:]LIST:RANGe<ri>:RLEVel................................................................................... 695
[SENSe:]LIST:RANGe<ri>:SWEep:TIME.......................................................................... 695
[SENSe:]LIST:RANGe<ri>:SWEep:TIME:AUTO................................................................ 696
[SENSe:]LIST:RANGe<ri>:TRANsducer........................................................................... 696
[SENSe:]LIST:RANGe<ri>:BANDwidth:RESolution <RBW>
This command defines the resolution bandwidth for a spurious emission measurement
range.
Suffix:
<ri>
.
1..n
Selects the measurement range.
Configuring and Performing Measurements