User Manual
Remote Commands
R&S
®
FPL1000
759User Manual 1178.3370.02 ─ 09
● Working with Markers............................................................................................839
● Configuring Display Lines..................................................................................... 898
● Defining Limit Checks........................................................................................... 901
11.8.1 Defining the Frequency and Span
The commands required to configure the frequency and span settings in a remote envi-
ronment are described here. The tasks for manual operation are described in Chap-
ter 7.4, "Frequency and Span Configuration", on page 301.
● Defining the Frequency Range............................................................................. 759
● Adjusting Settings Automatically...........................................................................763
● Configuring Signal Tracking.................................................................................. 767
11.8.1.1 Defining the Frequency Range
The following commands are required to define the frequency range.
CALCulate<n>:MARKer<m>:FUNCtion:CENTer................................................................ 759
CALCulate<n>:MARKer<m>:FUNCtion:CSTep..................................................................760
DISPlay[:WINDow<n>][:SUBWindow<w>]:TRACe<t>:X:SPACing....................................... 760
[SENSe:]FREQuency:CENTer......................................................................................... 760
[SENSe:]FREQuency:CENTer:STEP................................................................................761
[SENSe:]FREQuency:CENTer:STEP:AUTO......................................................................761
[SENSe:]FREQuency:CENTer:STEP:LINK........................................................................761
[SENSe:]FREQuency:CENTer:STEP:LINK:FACTor............................................................762
[SENSe:]FREQuency:OFFSet.........................................................................................762
[SENSe:]FREQuency:SPAN............................................................................................762
[SENSe:]FREQuency:SPAN:FULL...................................................................................763
[SENSe:]FREQuency:STARt........................................................................................... 763
[SENSe:]FREQuency:STOP............................................................................................763
CALCulate<n>:MARKer<m>:FUNCtion:CENTer
This command matches the center frequency to the frequency of a marker.
If you use the command in combination with a delta marker, that delta marker is turned
into a normal marker.
Suffix:
<n>
.
Window
<m> Marker
Example:
CALC:MARK2:FUNC:CENT
Sets the center frequency to the frequency of marker 2.
Manual operation: See "Center Frequency = Marker Frequency" on page 362
Setting Basic Spectrum RF Measurement Parameters