User Manual
Remote Commands
R&S
®
FPL1000
763User Manual 1178.3370.02 ─ 09
Parameters:
<Span> The minimum span for measurements in the frequency domain
is 10 Hz.
For SEM and spurious emission measurements, the minimum
span is 20 Hz.
Range: 0 Hz to fmax
*RST: Full span
Default unit: Hz
Manual operation: See "Zero Span" on page 97
See "Span" on page 303
See "Zero Span" on page 304
See "Last Span" on page 304
[SENSe:]FREQuency:SPAN:FULL
This command restores the full span.
Manual operation:
See "Full Span" on page 304
[SENSe:]FREQuency:STARt <Frequency>
This command defines a start frequency for measurements in the frequency domain.
Parameters:
<Frequency> 0 to (fmax - min span)
*RST: 0
Default unit: HZ
Example:
FREQ:STAR 20MHz
Manual operation: See "Frequency Sweep" on page 97
See "Start / Stop" on page 304
[SENSe:]FREQuency:STOP <Frequency>
This command defines a stop frequency for measurements in the frequency domain.
Parameters:
<Frequency> min span to fmax
*RST: fmax
Default unit: HZ
Example:
FREQ:STOP 2000 MHz
Manual operation: See "Frequency Sweep" on page 97
See "Start / Stop" on page 304
11.8.1.2 Adjusting Settings Automatically
The commands required to adjust settings automatically in a remote environment are
described here.
Setting Basic Spectrum RF Measurement Parameters