User Manual
Remote Commands
R&S
®
FPL1000
804User Manual 1178.3370.02 ─ 09
Manual operation: See "Calibrate Reflection Short" on page 294
See "Calibrate Reflection Open" on page 294
[SENSe:]CORRection:METHod <Type>
This command selects the type of measurement to be performed with the generator.
This command is only available if the Tracking Generator is active (see
OUTPut<up>[:STATe] on page 800).
Parameters:
<Type> REFLection
Selects reflection measurements.
TRANsmission
Selects transmission measurements.
*RST: TRANsmission
Example:
CORR:METH TRAN
Sets the type of measurement to "transmission".
Manual operation: See "Calibrate Transmission" on page 293
See "Calibrate Reflection Short" on page 294
See "Calibrate Reflection Open" on page 294
[SENSe:]CORRection:RECall
This command restores the measurement configuration used for calibration.
This command is only available if the Tracking Generator is active (see
OUTPut<up>[:STATe] on page 800).
Example:
CORR:REC
Manual operation: See "Recall Cal. Settings" on page 295
[SENSe:]CORRection:TRANsducer:GENerate <Name>
This command uses the normalized measurement data to generate a transducer factor
with up to 1001 points. The trace data is converted to a transducer with unit dB and
stored in a file with the specified name and the suffix .trd under
C:\ProgramData\Rohde-Schwarz\ZNL-FPL\trd. The frequency points are allo-
cated in equidistant steps between start and stop frequency.
The generated transducer factor can be further adapted using the commands descri-
bed in Chapter 11.10.3, "Working with Transducers", on page 958).
Parameters:
<Name> '<name>'
Example:
CORR:TRAN:GEN 'MyGenerator'
Creates the transducer file
C:\r_s\instr\trd\MyGenerator.trd.
Manual operation: See "Save as Trd Factor" on page 295
Setting Basic Spectrum RF Measurement Parameters