11.8.7 Configuring the Trace Display and Retrieving Trace Data
The commands required to work with traces are described here.
Commands required to export traces (and other result data) are described in Chap-
ter 11.9.5, "Storing Measurement Results", on page 941.
● Configuring Standard Traces................................................................................ 815
● Configuring Spectrograms.................................................................................... 821
● Using Trace Mathematics..................................................................................... 829
● Retrieving Trace Results.......................................................................................831
● Formats for Returned Values: ASCII Format and Binary Format..........................834
● Importing and Exporting Traces............................................................................ 835
● Programming Example: Configuring a Spectrogram.............................................837
11.8.7.1 Configuring Standard Traces
Useful commands for trace configuration described elsewhere
●
DISPlay[:WINDow<n>][:SUBWindow<w>]:TRACe<t>:Y:SPACing
on page 781
●
DISPlay[:WINDow<n>]:TRACe<t>:Y[:SCALe] on page 779
Remote commands exclusive to trace configuration
DISPlay[:WINDow<n>]:TRACe<t>:MODE.........................................................................815
DISPlay[:WINDow<n>][:SUBWindow<w>]:TRACe<t>:MODE:HCONtinuous.........................816
DISPlay[:WINDow<n>][:SUBWindow<w>]:TRACe<t>[:STATe]............................................ 817
DISPlay[:WINDow<n>][:SUBWindow<w>]:TRACe<t>:SMOothing:APERture........................817
DISPlay[:WINDow<n>][:SUBWindow<w>]:TRACe<t>:SMOothing[:STATe]........................... 818
[SENSe:]AVERage<n>:COUNt........................................................................................818
[SENSe:]AVERage<n>[:STATe<t>]...................................................................................819
[SENSe:]AVERage<n>:TYPE..........................................................................................819
[SENSe:][WINDow<n>:]DETector<t>[:FUNCtion]...............................................................819
[SENSe:][WINDow<n>:]DETector<t>[:FUNCtion]:AUTO..................................................... 820
TRACe<n>:COPY..........................................................................................................821
DISPlay[:WINDow<n>]:TRACe<t>:MODE <Mode>
This command selects the trace mode. If necessary, the selected trace is also activa-
ted.
In case of max hold, min hold or average trace mode, you can set the number of single
measurements with [SENSe:]SWEep:COUNt. Note that synchronization to the end of
the measurement is possible only in single sweep mode.