User Manual

Remote Commands
R&S
®
FPL1000
818User Manual 1178.3370.02 ─ 09
<w> subwindow
<t> Trace
Parameters:
<Aperture> Range: 1 to 50
*RST: 2
Default unit: PCT
Example:
DISP3:TRAC2:SMO:APER 5
Defines an aperture of 5% for trace 2 in window 3
Manual operation: See "Smoothing" on page 395
DISPlay[:WINDow<n>][:SUBWindow<w>]:TRACe<t>:SMOothing[:STATe] <State>
This command turns trace smoothing for a particular trace on and off.
If enabled, the trace is smoothed by the value specified using DISPlay[:
WINDow<n>][:SUBWindow<w>]:TRACe<t>:SMOothing:APERture on page 817.
For more information see "Trace Smoothing" on page 392.
Suffix:
<n>
.
Window
<w> subwindow
<t> Trace
Parameters:
<State> ON | OFF | 0 | 1
OFF | 0
Switches the function off
ON | 1
Switches the function on
Example:
DISP3:TRAC2:SMO ON
Turns on trace smoothing for trace 2 in window 3
Manual operation: See "Smoothing" on page 395
[SENSe:]AVERage<n>:COUNt <AverageCount>
This command defines the number of sweeps that the application uses to average
traces.
In case of continuous sweep mode, the application calculates the moving average over
the average count.
In case of single sweep mode, the application stops the measurement and calculates
the average after the average count has been reached.
Suffix:
<n>
.
irrelevant
Setting Basic Spectrum RF Measurement Parameters