User Manual
Remote Commands
R&S
®
FPL1000
822User Manual 1178.3370.02 ─ 09
CALCulate<n>:SGRam:FRAMe:COUNt........................................................................... 823
CALCulate<n>:SPECtrogram:FRAMe:COUNt...................................................................823
CALCulate<n>:SGRam:FRAMe:SELect........................................................................... 823
CALCulate<n>:SPECtrogram:FRAMe:SELect...................................................................823
CALCulate<n>:SGRam:HDEPth......................................................................................824
CALCulate<n>:SPECtrogram:HDEPth..............................................................................824
CALCulate<n>:SGRam:LAYout........................................................................................824
CALCulate<n>:SPECtrogram:LAYout............................................................................... 824
CALCulate<n>:SGRam[:STATe].......................................................................................825
CALCulate<n>:SPECtrogram[:STATe].............................................................................. 825
CALCulate<n>:SGRam:THReedim[:STATe]...................................................................... 825
CALCulate<n>:SPECtrogram:THReedim[:STATe]..............................................................825
CALCulate<n>:SGRam:TRACe....................................................................................... 825
CALCulate<n>:SPECtrogram:TRACe...............................................................................825
CALCulate<n>:SGRam:TSTamp:DATA?...........................................................................826
CALCulate<n>:SPECtrogram:TSTamp:DATA?.................................................................. 826
CALCulate<n>:SGRam:TSTamp[:STATe]..........................................................................826
CALCulate<n>:SPECtrogram:TSTamp[:STATe]................................................................. 826
CALCulate<n>:SGRam:CLEar[:IMMediate]
CALCulate<n>:SPECtrogram:CLEar[:IMMediate]
This command resets the spectrogram and clears the history buffer.
Suffix:
<n>
.
Window
Example: //Reset the result display and clear the memory
CALC:SGR:CLE
Manual operation: See "Clear Spectrogram" on page 329
CALCulate<n>:SGRam:CONTinuous <State>
CALCulate<n>:SPECtrogram:CONTinuous <State>
This command determines whether the results of the last measurement are deleted
before starting a new measurement in single sweep mode.
This setting applies to all spectrograms in the channel setup.
Suffix:
<n>
.
Window
Parameters:
<State> ON | OFF | 0 | 1
OFF | 0
Switches the function off
ON | 1
Switches the function on
Setting Basic Spectrum RF Measurement Parameters