User Manual
Remote Commands
R&S
®
FPL1000
858User Manual 1178.3370.02 ─ 09
If necessary, the command activates the delta marker first.
Suffix:
<n>
.
Window
<m> Marker
Return values:
<Position> Position of the delta marker in relation to the reference marker.
Example:
CALC:DELT3:X:REL?
Outputs the frequency of delta marker 3 relative to marker 1 or
relative to the reference position.
Usage: Query only
Manual operation: See "Marker 1/Marker 2/Marker 3/Marker 4" on page 244
See "Marker 1/Marker 2/Marker 3" on page 248
CALCulate<n>:DELTamarker<m>:Y
Queries the result at the position of the specified delta marker.
Suffix:
<n>
.
1..n
<m> 1..n
Return values:
<Result> Result at the position of the delta marker.
The unit is variable and depends on the one you have currently
set.
Default unit: DBM
CALCulate<n>:MARKer<m>:Y
Queries the result at the position of the specified marker.
Suffix:
<n>
.
1..n
<m> 1..n
Return values:
<Result> Default unit: DBM
Manual operation: See "Marker Table" on page 117
See "Marker Peak List" on page 118
11.8.8.6 Marker Search (Spectrograms)
The following commands automatically define the marker and delta marker position in
the spectrogram.
Setting Basic Spectrum RF Measurement Parameters