User Manual

Remote Commands
R&S
®
FPL1000
903User Manual 1178.3370.02 ─ 09
<li> Limit line
Parameters:
<SpanSetting> FREQuency | TIME
FREQuency
For limit lines that apply to a range of frequencies.
TIME
For limit lines that apply to a period of time.
*RST: FREQuency
Example:
CALC:LIM:CONT:DOM FREQ
Select a limit line in the frequency domain.
Manual operation: See "X-Axis" on page 430
CALCulate<n>:LIMit<li>:CONTrol:MODE <Mode>
This command selects the horizontal limit line scaling.
Suffix:
<n>
.
irrelevant
<li> Limit line
Parameters:
<Mode> ABSolute
Limit line is defined by absolute physical values (Hz or s).
RELative
Limit line is defined by relative values related to the center fre-
quency (frequency domain) or the left diagram border (time
domain).
*RST: ABSolute
CALCulate<n>:LIMit<li>:CONTrol:OFFSet <Offset>
This command defines an offset for a complete limit line.
Compared to shifting the limit line, an offset does not actually change the limit line defi-
nition points.
Suffix:
<n>
.
irrelevant
<li> Limit line
Parameters:
<Offset> Numeric value.
The unit depends on the scale of the x-axis.
*RST: 0
Default unit: HZ
Manual operation: See "X-Offset" on page 427
Setting Basic Spectrum RF Measurement Parameters