User Manual
Remote Commands
R&S
®
FPL1000
979User Manual 1178.3370.02 ─ 09
OFF
The option is indicated as "B7J"
ON
The 40 MHz wideband is used.
The option is indicated as "B7J, 140".
HIGH
The 80 MHz wideband is used.
The option is indicated as "B7J, 122".
*RST: OFF
SYSTem:REVision[:STRing] <Name>
Sets the response to the REV? query to the defined string (HP emulation only, see
SYSTem:LANGuage on page 978).
Parameters:
<Name>
Example: Define the system language:
SYST:LANG '8563E'
Query the revision:
REV?
Response:
920528
Set the response to 'NewRevision':
SYST:REV:STR 'NewRevision'
Query the response:
SYST:REV:STR?
Response:
NewRevision
Manual operation:
See "Revision String" on page 586
SYSTem:RSWeep <State>
Controls a repeated sweep of the E1 and MKPK HI HP model commands (for details
on the commands refer to Chapter 11.11.2, "Reference: GPIB Commands of Emulated
HP Models", on page 980). If the repeated sweep is OFF, the marker is set without
sweeping before.
This command is only available if a HP language is selected using SYSTem:LANGuage
on page 978
Parameters:
<State> ON | OFF | 1 | 0
*RST: 0
Example:
SYSTem:RSW ON
Manual operation: See "Sweep Repeat" on page 585
Emulating Other Instruments' Commands