User Manual

Common Instrument Functions
R&S
®
FPL1000
150User Manual 1178.3370.02 ─ 03
Name ..........................................................................................................................150
Unit .............................................................................................................................150
Compatibility ...............................................................................................................150
Activating / Deactivating .............................................................................................150
Comment ....................................................................................................................150
Included Transducer Lines in Overview (View Filter) .................................................150
Adjust Ref Level .........................................................................................................151
Create New Line ........................................................................................................ 151
Edit Line ..................................................................................................................... 151
Copy Line ...................................................................................................................151
Delete Line .................................................................................................................151
Name
The name of the stored transducer line.
Unit
The unit in which the y-values of the data points of the transducer line are defined.
The following units are available:
dB
dBm
dBmV
dBμV
dBμV/m
dBμA
dBμA/m
dBpW
dBpT
Compatibility
Indicates whether the transducer factors are compatible with the current measurement
settings.
For more information on which conditions a transducer line must fulfill to be compati-
ble, see Chapter 6.3.6.1, "Basics on Transducer Factors", on page 147.
Activating / Deactivating
Activates/deactivates the transducer line. Up to 8 transducer lines can be active at the
same time.
Remote command:
[SENSe:]CORRection:TRANsducer:SELect on page 822
[SENSe:]CORRection:TRANsducer[:STATe] on page 822
Comment
An optional description of the transducer line.
Included Transducer Lines in Overview (View Filter)
Defines which of the stored transducer lines are included in the overview. The view can
be restricted to compatible transducer lines only or include all transducer lines found.
Whether a line is compatible or not is indicated in the Compatibility setting.
General Instrument Setup