User Manual
The Spectrum Application (RF Measurements)
R&S
®
FPL1000
340User Manual 1178.3370.02 ─ 03
File contents Explanation
File data section
0;9000;150000;1000;79500;-25.006643295288086;-
12.006643295288086;PASS;
0;9000;150000;1000;101022.11126961483;-47.075
111389160156;-34.075111389160156;PASS;
0;9000;150000;1000;58380.171184022824;-47.079
341888427734;-34.079341888427734;PASS;
Measured peak values:
<range number>;
<start frequency>;
<stop frequency>;
<resolution bandwidth of range>;
<frequency of peak>;
<absolute power in dBm of peak>;
<distance to the limit line in dB>; (positive value
means above the limit)
<limit fail (pass = 0, fail =1)>;
7.2.8 Time Domain Power Measurement
The Time Domain Power measurement determines the power of a signal in the time
domain.
A time domain power measurement is only possible for zero span.
● About the Measurement........................................................................................340
● Time Domain Power Results.................................................................................340
● Time Domain Power Basics - Range Definition Using Limit Lines........................341
● Time Domain Power Configuration....................................................................... 342
● How to Measure Powers in the Time Domain.......................................................343
● Measurement Example......................................................................................... 343
7.2.8.1 About the Measurement
Using the Time Domain Power measurement function, the R&S FPL1000 determines
the power of the signal in zero span by summing up the power at the individual mea-
surement points and dividing the result by the number of measurement points. Thus it
is possible to measure the power of TDMA signals during transmission, for example, or
during the muting phase. Both the mean power and the RMS power can be measured.
For this measurement, the sample detector is activated.
7.2.8.2 Time Domain Power Results
Several different power results can be determined simultaneously:
Mode Description
Peak Peak value from the points of the displayed trace or a segment
thereof.
RMS RMS value from the points of the displayed trace or a segment
thereof.
Measurements and Results