User Manual

Remote Commands
R&S
®
FPL1000
618User Manual 1178.3370.02 ─ 03
CALC:MARK:FUNC:TOI ON
//Activate TOI measurement.
//--------------Performing the Measurement-----
INIT:CONT OFF
//Selects single sweep mode.
CALC:MARK:FUNC:TOI:SEAR ONCE
//Initiates a search for signals in the current trace.
//---------------Retrieving Results-------------
CALC:MARK:FUNC:TOI:RES?
//Returns the TOI.
8.6.11 Measuring the AM Modulation Depth
All remote control commands specific to AM modulation depth measurements are
described here.
Configuring and Performing the Measurement..................................................... 618
Example: Measuring the AM Modulation Depth....................................................619
8.6.11.1 Configuring and Performing the Measurement
The following commands control the measurement.
Useful commands for AM modulation depth described elsewhere
CALCulate<n>:DELTamarker<m>:X on page 712
CALCulate<n>:DELTamarker<m>:X:RELative? on page 726
CALCulate<n>:MARKer<m>:X on page 714
Remote commands exclusive to AM modulation depth measurements
CALCulate<n>:MARKer<m>:FUNCtion:MDEPth[:STATe]...................................................618
CALCulate<n>:MARKer<m>:FUNCtion:MDEPth:SEARchsignal ONCE............................... 619
CALCulate<n>:MARKer<m>:FUNCtion:MDEPth:RESult?...................................................619
CALCulate<n>:MARKer<m>:FUNCtion:MDEPth[:STATe] <State>
This command turns the AM Modulation Depth measurement on and off.
To work correctly, the measurement requires an AM modulated signal.
Suffix:
<n>
.
Window
<m> Marker
Configuring and Performing Measurements