User Manual

Remote Commands
R&S
®
FPL1000
708User Manual 1178.3370.02 ─ 03
CALC:MARK2:X?
CALC:MARK2:Y?
CALC:MARK2:SGR:FRAM?
//Queries the frequency (x), level (y) and frame values of marker 2.
CALC:DELT1:X?
CALC:DELT1:Y?
CALC:DELT1:SGR:FRAM?
//Queries the frequency (x), level (y) and frame values of deltamarker 1.
CALC:DELT3:X?
CALC:DELT3:Y?
CALC:DELT3:SGR:FRAM?
//Queries the frequency (x), level (y) and frame values of deltamarker 3.
CALC:SGR:TST:DATA? ALL
//Queries the time stamps of all stored frames.
CALC:SGR:FRAM:SEL -1
//Selects the frame that was captured 1 second after measurement start (Note the
//negative value!). This frame is displayed in the Spectrum window.
TRAC:DATA? SGR
//Retrieves the trace data for the spectrogram. For each frame, the power level
//and frequency at each sweep point are returned.
TRAC:DATA? TRACE1
//Retrieves the trace data for the selected frame only.
8.8.8 Working with Markers
The commands required to work with markers and marker functions in a remote envi-
ronment are described here. The tasks for manual operation are described in Chap-
ter 7.9, "Marker Usage", on page 421.
In the Spectrum application, markers are identical in all windows. Thus, the suffix <n>
for the window is generally irrelevant.
Setting Up Individual Markers............................................................................... 709
General Marker Settings....................................................................................... 714
Configuring and Performing a Marker Search.......................................................716
Positioning the Marker.......................................................................................... 719
Retrieving Marker Results.....................................................................................725
Marker Search (Spectrograms).............................................................................728
Fixed Reference Marker Settings..........................................................................738
Marker Peak Lists................................................................................................. 740
Noise Measurement Marker..................................................................................743
Phase Noise Measurement Marker.......................................................................744
Band Power Marker.............................................................................................. 747
n dB Down Marker................................................................................................ 750
Setting Basic Spectrum RF Measurement Parameters