See also INITiate<n>:CONTinuous on page 536.
Suffix:
<n>
.
Window
<m> Marker
Return values:
<Result> Result at the marker position.
The unit is variable and depends on the one you have currently
set.
Example:
INIT:CONT OFF
Switches to single measurement mode.
CALC:MARK2 ON
Switches marker 2.
INIT;*WAI
Starts a measurement and waits for the end.
CALC:MARK2:Y?
Outputs the measured value of marker 2.
Usage: Query only
Manual operation: See " Marker Table " on page 254
See " Marker Peak List " on page 254
8.8.8.6 Marker Search (Spectrograms)
The following commands automatically define the marker and delta marker position in
the spectrogram.
The usage of these markers is demonstrated in Chapter 8.8.7.6, "Programming Exam-
ple: Configuring a Spectrogram", on page 706.
Using Markers
The following commands control spectrogram markers.
Useful commands for spectrogram markers described elsewhere
The following commands define the horizontal position of the markers.
●
CALCulate<n>:MARKer<m>:MAXimum:LEFT on page 720
●
CALCulate<n>:MARKer<m>:MAXimum:NEXT on page 720
●
CALCulate<n>:MARKer<m>:MAXimum[:PEAK] on page 720
●
CALCulate<n>:MARKer<m>:MAXimum:RIGHt on page 721
●
CALCulate<n>:MARKer<m>:MINimum:LEFT on page 721
●
CALCulate<n>:MARKer<m>:MINimum:NEXT on page 722
●
CALCulate<n>:MARKer<m>:MINimum[:PEAK] on page 722
●
CALCulate<n>:MARKer<m>:MINimum:RIGHt on page 722
Setting Basic Spectrum RF Measurement Parameters