User Manual
Remote Commands
R&S
®
FPL1000
773User Manual 1178.3370.02 ─ 03
Manual operation: See " Data Points " on page 500
CALCulate<n>:LIMit<k>:LOWer:MARGin <Margin>
This command defines an area around a lower limit line where limit check violations
are still tolerated.
Suffix:
<n>
.
irrelevant
<k> Limit line
Parameters:
<Margin> numeric value
*RST: 0
Default unit: dB
Manual operation: See " Margin " on page 500
CALCulate<n>:LIMit<k>:LOWer:MODE
<Mode>
This command selects the vertical limit line scaling.
Suffix:
<n>
.
Window
<k> Limit line
Parameters:
<Mode> ABSolute
Limit line is defined by absolute physical values.
The unit is variable.
RELative
Limit line is defined by relative values related to the reference
level (dB).
*RST: ABSolute
Manual operation: See " X-Axis " on page 500
CALCulate<n>:LIMit<k>:LOWer:OFFSet <Offset>
This command defines an offset for a complete lower limit line.
Compared to shifting the limit line, an offset does not actually change the limit line defi-
nition points.
Suffix:
<n>
.
Window
<k> Limit line
Setting Basic Spectrum RF Measurement Parameters