User Manual

Remote Commands
R&S
®
FPL1000
775User Manual 1178.3370.02 ─ 03
Parameters:
<State> ON | OFF | 1 | 0
*RST: 0
Manual operation: See " Visibility " on page 497
CALCulate<n>:LIMit<k>:LOWer:THReshold <Threshold>
This command defines a threshold for relative limit lines.
The R&S FPL1000 uses the threshold for the limit check, if the limit line violates the
threshold.
Suffix:
<n>
.
irrelevant
<k> Limit line
Parameters:
<Threshold> Numeric value.
The unit depends on CALCulate<n>:LIMit<k>:UNIT
on page 775.
*RST: -200 dBm
Manual operation: See " Threshold " on page 499
CALCulate<n>:LIMit<k>:NAME <Name>
This command selects a limit line that already exists or defines a name for a new limit
line.
Suffix:
<n>
.
Window
<k> Limit line
Parameters:
<Name> String containing the limit line name.
*RST: REM1 to REM8 for lines 1 to 8
Manual operation: See " Name " on page 499
CALCulate<n>:LIMit<k>:UNIT <Unit>
This command defines the unit of a limit line.
Suffix:
<n>
.
irrelevant
<k> Limit line
Setting Basic Spectrum RF Measurement Parameters