Manual operation: See " Copy Line " on page 498
CALCulate<n>:LIMit<k>:DELete
This command deletes a limit line.
Suffix:
<n>
.
Window
<k> Limit line
Usage: Event
Manual operation: See " Delete Line " on page 498
CALCulate<n>:LIMit<k>:STATe <State>
This command turns the limit check for a specific limit line on and off.
To query the limit check result, use CALCulate<n>:LIMit<k>:FAIL?.
Note that a new command exists to activate the limit check and define the trace to be
checked in one step (see CALCulate<n>:LIMit<k>:TRACe<t>:CHECk
on page 780).
Suffix:
<n>
.
irrelevant
<k> Limit line
Parameters:
<State> ON | OFF | 1 | 0
*RST: 0
Example:
CALC:LIM:STAT ON
Switches on the limit check for limit line 1.
Manual operation: See " Disable All Lines " on page 498
CALCulate<n>:LIMit<k>:TRACe<t>:CHECk <State>
This command turns the limit check for a specific trace on and off.
To query the limit check result, use CALCulate<n>:LIMit<k>:FAIL?.
Suffix:
<n>
.
Window
<k> Limit line
<t> Trace
Parameters:
<State> ON | OFF | 1 | 0
*RST: 0