Example:
CALC:LIM3:TRAC2:CHEC ON
Switches on the limit check for limit line 3 on trace 2.
Manual operation: See " Traces to be Checked " on page 497
MMEMory:LOAD<n>:LIMit <FileName>
Loads the limit line from the selected file in .CSV format.
Parameters:
<FileName> String containing the path and name of the CSV import file.
Example:
MMEM:LOAD:LIM 'C:\TEST.CSV'
Manual operation: See " Import " on page 501
MMEMory:STORe<n>:LIMit
<FileName>,<LimitLineName>
This command exports limit line data to an ASCII (CSV) file.
For details on the file format see Chapter 7.11.2.4, "Reference: Limit Line File Format",
on page 506.
Suffix:
<n>
.
irrelevant
Parameters:
<FileName> String containing the path and name of the target file.
<LimitLineName> Name of the limit line to be exported.
Example:
MMEM:STOR:LIM 'C:\TEST', 'UpperLimitLine'
Stores the limit line named "UpperLimitLine" in the file
TEST.CSV.
Manual operation: See " Export " on page 501
Checking the Results of a Limit Check
CALCulate<n>:LIMit<k>:CLEar[:IMMediate]......................................................................781
CALCulate<n>:LIMit<k>:FAIL?........................................................................................ 782
CALCulate<n>:LIMit<k>:CLEar[:IMMediate]
This command deletes the result of the current limit check.
The command works on all limit lines in all measurement windows at the same time.
Suffix:
<n>, <k>
.
irrelevant
Example:
CALC:LIM:CLE
Deletes the result of the limit check.