AT A GLANCE Comprising five powerful models The R&S®NGP800 DC power supply series, comprising five models with 400 W or 800 W, provides maximum power at a variety of operating points. The two or four 200 W outputs can each supply up to 64 V or up to 20 A. Electrically equivalent and galvanically isolated outputs can be wired in series or parallel for up to 250 V or 80 A.
BOOST YOUR EFFICIENCY WITH ... ... full flexibility ... full safety ►► 5" ►► Protection high-resolution touch display functions limits ►► Safe working environment ▷▷ page 8 ►► FlexPower ►► Safety ►► Four power supplies in a single instrument and serial operation page 4 ►► Parallel ▷▷ ... full connectivity ...
FULL FLEXIBILITY 5" high-resolution touch display The large high-resolution touch display makes operation easy. Quickly navigate through the menus to access all functions and settings. Enter values much faster using the virtual keyboard instead of turning the knob. The home screen gives you a clear overview of all your channels.
Four power supplies in a single instrument Save costs and space on your bench or in your rack by powering up to four DUTs with a single instrument. Each output is completely independent and floating. All outputs can operate in constant voltage (CV) or constant current (CC) mode with automatic crossover and mode indication. A separate output button allows you to synchronously switch all channels on or off. This is crucial for circuitries that can be damaged if one voltage rail is present without the other.
FULL FUNCTIONALITY Ramp function (EasyRamp) Output delay To control inrush currents, some test setups require the continuous rise of the supply voltage instead of a rapid jump. Increase the output voltage continuously within a timeframe of 10 ms to 60 s with the EasyRamp function. Turn on each channel individually with a delay to meet the requirements of stateof-the-art microcontrollers that use multiple supply voltages and demand specific power-up sequences.
Arbitrary function (QuickArb) Data logging Emulate the normal behaviors of your power subsystems early in the design process and simulate power problems for DUT design verification. Logging data is key to long-term monitoring, reviewing test setups and repeating test conditions when analyzing power behaviors or optimizing power consumption. The QuickArb function lets you generate voltages that vary over time and current sequences of output changes with dwell times down to 1 ms.
FULL SAFETY Protection functions Protecting your DUT is crucial to limit testing. The R&S®NGP800 power supplies include overcurrent protection (OCP), overvoltage protection (OVP) and overpower protection (OPP). The internal overtemperature protection (OTP) switches the power supply off if a thermal overload is imminent. You can set the maximum current, voltage and power separately for each channel.
FULL CONNECTIVITY Digital remote control Digital trigger I/O (R&S®NGP-K103 option) To meet the requirements of varying environments, an array of interfaces to remotely control your instrument is provided. Configure the eight pins of the digital I/O connector as inputs or outputs to generate trigger events for output control and indication. As an input, the trigger I/O can enable or inhibit outputs or start functions such as QuickArb or logging.
SPECIFICATIONS Definitions General Product data applies under the following conditions: ►► Three hours storage at ambient temperature followed by 30 minutes warm-up operation ►► All data is valid at 23 °C (–3 °C/+7 °C) after 30 minutes warm-up time.
Electrical specifications Outputs The channel outputs are galvanically isolated and not connected to ground. Number of output channels R&S®NGP802, R&S®NGP822 2 R&S®NGP804, R&S®NGP824, R&S®NGP814 4 R&S®NGP802, R&S®NGP822 max. 400 W R&S®NGP804, R&S®NGP824, R&S®NGP814 max.
Output measurements Measurement functions voltage, current, power, energy Readback resolution Voltage 1 mV Current 0.5 mA Readback accuracy Voltage Current Temperature coefficient (per °C) ±(% of output + offset) R&S®NGP802, R&S®NGP804, R&S®NGP814 (CH1, CH2) < 0.05 % + 5 mV R&S®NGP822, R&S®NGP824, R&S®NGP814 (CH3, CH4) < 0.05 % + 10 mV ±(% of output + offset) R&S®NGP802, R&S®NGP804, R&S®NGP814 (CH1, CH2) < 0.1 % + 20 mA R&S®NGP822, R&S®NGP824, R&S®NGP814 (CH3, CH4) < 0.
Special functions Output ramp function EasyRamp EasyRamp time 10 ms to 60 s (1 ms increments) Output delay Synchronicity < 1 ms (typ.
General data Environmental conditions Temperature Humidity operating temperature range +5 °C to +40 °C storage temperature range –20 °C to +70 °C noncondensing 5 % to 95 % Power rating Mains nominal voltage 100 V to 250 V Mains frequency 50 Hz to 60 Hz Maximum power consumption Main fuses R&S®NGP802, R&S®NGP822 650 W R&S®NGP804, R&S®NGP824, R&S®NGP814 1125 W internal (not user accessible) 16 A 250 V IEC 60127-2/7 fast acting EU: in line with Radio Equipment Directive 2014/53/EU applied st
ORDERING INFORMATION Designation Type Order No. Two-channel power supply, 400 W, 32 V/20 A R&S®NGP802 5601.4007.05 Four-channel power supply, 800 W, 32 V/20 A R&S®NGP804 5601.4007.02 Four-channel power supply, 800 W, 2 5 32 V/20 A, 2 × 64 V/10 A R&S®NGP814 5601.4007.04 Two-channel power supply, 400 W, 64 V/10 A R&S®NGP822 5601.4007.06 Four-channel power supply, 800 W, 64 V/10 A R&S®NGP824 5601.4007.03 R&S®NG-B105 5601.6000.02 Wireless LAN remote control R&S®NGP-K102 5601.6400.
Rohde & Schwarz Worldwide Local und personalized Customized and flexible Uncompromising quality Long-term dependability The Rohde & Schwarz electronics group offers innovative solutions in the following business fields: test and measurement, broadcast and media, secure communications, cybersecurity, monitoring and network testing.