User's Manual Part 1
Table Of Contents
- System Manual
- R&S®NV830x DTV Transmitters ATSC
- Volume 1
- Contents
- Safety Instructions
- Design and Characteristics
- Contents
- 1 Design and Function
- 2 Specifications
- Installation
- Contents
- 1 Equipment Supplied 1
- 2 Overview 3
- 3 Setting Up Transmitter 4
- 4 Ventilation System 9
- 5 AC Power Supply 14
- 6 Amplifiers 19
- 7 Connecting Antenna/Dummy Antenna to RF Connector 20
- 8 Connection Panel 23
- 1 Equipment Supplied
- 2 Overview
- 3 Setting Up Transmitter
- 4 Ventilation System
- 5 AC Power Supply
- 6 Amplifiers
- 7 Connecting Antenna/Dummy Antenna to RF Connector
- 8 Connection Panel
- Contents
- Commissioning
- Contents
- 1 General Information 1
- 2 Preparing for Transmitter Startup 3
- 2.1 Preparing for Local Operation 3
- 2.2 Checking and Setting System and Operating Parameters 3
- 2.3 R&S NetCCU800 3
- 2.4 Setting Transmitter Type 9
- 2.5 Entering Exciter Settings 11
- 2.6 Entering Output Stage Settings 19
- 2.7 Setting Transmitter Output Power 21
- 2.8 Calibrating Power Displays 22
- 3 Completion of Startup Procedure 26
- 4 Precorrection 31
- 1 General Information
- 2 Preparing for Transmitter Startup
- 2.1 Preparing for Local Operation
- 2.2 Checking and Setting System and Operating Parameters
- 2.3 R&S NetCCU800
- 2.4 Setting Transmitter Type
- 2.5 Entering Exciter Settings
- 2.6 Entering Output Stage Settings
- 2.7 Setting Transmitter Output Power
- 2.8 Calibrating Power Displays
- 3 Completion of Startup Procedure
- 4 Precorrection
- Contents
Chapter 4 Commissioning
2098.0188.72 - 4.3 - E-1
2 Preparing for Transmitter Startup
Local operation of the R&S NetCCU800 includes all the information calls for the system pa-
rameters and their settings, complete with intuitive graphical menus.
Remote operation via a web browser is possible only if a PC or notebook is connected to
the front panel of the R&S NetCCU800.
2.1 Preparing for Local Operation
To prepare for local control, proceed as follows:
Press the LOCAL key on the R&S NetCCU800.
Its yellow LED should light up.
2.2 Checking and Setting System and Operating
Parameters
In order to bring the transmitter into operation, you must check and set the following system
and operating parameters.
2.3 R&S NetCCU800
2.3.1 Switching On R&S NetCCU800
Connect the R&S NetCCU800 to the AC power supply.
After a few seconds, the unit boots up and the entry screen indicates when it is ready for
use.
Local operation of the R&S NetCCU800 includes all the information calls for the system pa-
rameters and their settings, complete with intuitive graphical menus.
Remote operation via a web browser is possible only if a PC or notebook is connected to
the front panel of the R&S NetCCU800.
2.3.2 Changing User Type
To configure the transmitter by means of the R&S NetCCU800, you must have configuration
rights.