User's Manual Part 1

Table Of Contents
Chapter 4 Commissioning
2098.0188.72 - 4.9 - E-1
Notes
Manual settings for remote connection should only be entered in offline mode (context
menu: Edit Offline) and then activated with Submit Changes (context menu).
The IP address must not be in the same network as the front ETHERNET interface.
To allow automatic integration in a network (DHCP Client activated), the network must
contain a DHCP server.
2.4 Setting Transmitter Type
Select NetCCU > Setup > TX Setup.
The Tx Setup window opens.
You can use the Tx Setup window to make system-specific settings and to define standby
behavior.
The table below describes the adjustable parameters:
Function Explanation
Tx Mode Used to select the transmitter standard
NoExciter: R&S NetCCU800 is operated as a standalone instrument
(e.g. in combination with the DVB-T receiver module option)
Multi: Both exciters in a transmitter use different standards
FM: Analog sound broadcasting standard
ATV: Analog TV standard
ATSC: Digital TV standard (USA)
DAB: Digital audio broadcasting standard
DVB: Digital TV standard (Europe)
DTMB: Digital TV standard (South America, Asia, Europe)
MediaFLO™: Digital TV standard (USA)
ISDB-T: Digital TV standard (Brazil, Japan)
ATV Mode Selection only possible if ATV is set under Tx Mode
Comb Single: Vision signal and sound signal are transmitted via one
amplifier (same channel) (single = 1 sound carrier)
Comb Dual: Vision signal and sound signal are transmitted via one
amplifier (same channel) (dual = 2 sound carriers)