User's Manual Part 1
Table Of Contents
- System Manual
- R&S®NV830x DTV Transmitters ATSC
- Volume 1
- Contents
- Safety Instructions
- Design and Characteristics
- Contents
- 1 Design and Function
- 2 Specifications
- Installation
- Contents
- 1 Equipment Supplied 1
- 2 Overview 3
- 3 Setting Up Transmitter 4
- 4 Ventilation System 9
- 5 AC Power Supply 14
- 6 Amplifiers 19
- 7 Connecting Antenna/Dummy Antenna to RF Connector 20
- 8 Connection Panel 23
- 1 Equipment Supplied
- 2 Overview
- 3 Setting Up Transmitter
- 4 Ventilation System
- 5 AC Power Supply
- 6 Amplifiers
- 7 Connecting Antenna/Dummy Antenna to RF Connector
- 8 Connection Panel
- Contents
- Commissioning
- Contents
- 1 General Information 1
- 2 Preparing for Transmitter Startup 3
- 2.1 Preparing for Local Operation 3
- 2.2 Checking and Setting System and Operating Parameters 3
- 2.3 R&S NetCCU800 3
- 2.4 Setting Transmitter Type 9
- 2.5 Entering Exciter Settings 11
- 2.6 Entering Output Stage Settings 19
- 2.7 Setting Transmitter Output Power 21
- 2.8 Calibrating Power Displays 22
- 3 Completion of Startup Procedure 26
- 4 Precorrection 31
- 1 General Information
- 2 Preparing for Transmitter Startup
- 2.1 Preparing for Local Operation
- 2.2 Checking and Setting System and Operating Parameters
- 2.3 R&S NetCCU800
- 2.4 Setting Transmitter Type
- 2.5 Entering Exciter Settings
- 2.6 Entering Output Stage Settings
- 2.7 Setting Transmitter Output Power
- 2.8 Calibrating Power Displays
- 3 Completion of Startup Procedure
- 4 Precorrection
- Contents
Chapter 4 Commissioning
2098.0188.72 - 4.14 - E-1
2.5.3 Switching Off Precorrector
1. Select Exciter A ATSC > Precorrection > Linear.
The Linear window opens.
2. Set Linear Correction to Off.
The linear precorrector path is deactivated.
3. Select Exciter A ATSC > Precorrection > Nonlinear.
The Nonlinear window opens.
On Input Loss For setting the behavior in the event of a defective input signal (synchro-
nization error)
– No Mute: The output signal is not suppressed (only effective with
MFN)
– Mute: The output signal is suppressed if the data rate is incorrect (rec-
ommended for SFN)
Type of Loss of Input Selection:
– Warning: If the input signal fails, only a warning will be generated.
– Fault: If the input signal fails, an additional sum fault will be generated
after the time set under Fail Delay Time has elapsed. In the case of
transmitters with exciter standby, switchover to the second exciter
occurs.
Fail Delay Time For setting a delay time which must elapse after an input signal dropout
before a general fault is generated.