User's Manual Part 1
Table Of Contents
- System Manual
- R&S®NV830x DTV Transmitters ATSC
- Volume 1
- Contents
- Safety Instructions
- Design and Characteristics
- Contents
- 1 Design and Function
- 2 Specifications
- Installation
- Contents
- 1 Equipment Supplied 1
- 2 Overview 3
- 3 Setting Up Transmitter 4
- 4 Ventilation System 9
- 5 AC Power Supply 14
- 6 Amplifiers 19
- 7 Connecting Antenna/Dummy Antenna to RF Connector 20
- 8 Connection Panel 23
- 1 Equipment Supplied
- 2 Overview
- 3 Setting Up Transmitter
- 4 Ventilation System
- 5 AC Power Supply
- 6 Amplifiers
- 7 Connecting Antenna/Dummy Antenna to RF Connector
- 8 Connection Panel
- Contents
- Commissioning
- Contents
- 1 General Information 1
- 2 Preparing for Transmitter Startup 3
- 2.1 Preparing for Local Operation 3
- 2.2 Checking and Setting System and Operating Parameters 3
- 2.3 R&S NetCCU800 3
- 2.4 Setting Transmitter Type 9
- 2.5 Entering Exciter Settings 11
- 2.6 Entering Output Stage Settings 19
- 2.7 Setting Transmitter Output Power 21
- 2.8 Calibrating Power Displays 22
- 3 Completion of Startup Procedure 26
- 4 Precorrection 31
- 1 General Information
- 2 Preparing for Transmitter Startup
- 2.1 Preparing for Local Operation
- 2.2 Checking and Setting System and Operating Parameters
- 2.3 R&S NetCCU800
- 2.4 Setting Transmitter Type
- 2.5 Entering Exciter Settings
- 2.6 Entering Output Stage Settings
- 2.7 Setting Transmitter Output Power
- 2.8 Calibrating Power Displays
- 3 Completion of Startup Procedure
- 4 Precorrection
- Contents
Chapter 4 Commissioning
2098.0188.72 - 4.36 - E-1
Fig. 3 Typical curve for starting precorrection with amplitude precorrection switched off
4.3.3.3 Amplitude Precorrection
The procedure for amplitude precorrection is the same as that for phase precorrection.
If the first interpolation point brings about an improvement, deal similarly with the other in-
terpolation points.
1. Set the interpolation points more or less at the positions of the phase values.
2. Set all magnitudes to zero.
3. Starting with the interpolation point for the white level (low), change the magnitude (in
steps of ± 0.5 or smaller) in order to find the precorrection.
Note From here on it is a prerequisite that the precorrection for phase and amplitude has been
optimized at all interpolation points.