High signal fidelity with active probes
Single-ended active probes are used to accurately mea-
sure ground-referenced signals. They precisely measure
both high-speed and low-frequency signals for which it
is critical that the probe impedance places only a mini-
mal load on the test point. Rohde & Schwarz offers a va-
riety of models with a maximum bandwidth up to 6GHz.
Rohde & Schwarz single-ended active probes feature a high
input impedance of 1MΩ, a low input capacitance down
to 0.3pF and noise down to 2mV (RMS) referenced to the
input.
Wide dynamic range with additional offset
compensation
In addition to the wide dynamic range, Rohde & Schwarz
single-ended active probes also offer an offset compen-
sation. As a result, the DC component of the measured
signal can be compensated so that the signal components
of interest are displayed on the oscilloscope at maximum
resolution. The maximum input voltage of 30V ensures
that the probe is not damaged by overloads.
A low voltage, single-ended probe is typically used for
measuring high-speed, ground-referenced signals up to
12V.
Single-ended
broadband probes
Wide dynamic range: ±8 V, expandable with
additional offset compensation of ±12 V (±10 V for
R&S®RT-ZS60)
A particularly wide dynamic range, exceptionally
low offset and gain errors and the right accessories
make these probes the ideal accessory for
Rohde & Schwarz oscilloscopes.
Practical design: micro button for convenient instrument control
Diverse probe tips and ground cables are included as standard.
max. ±30 V nondestructive input voltage
Dynamic range
±8 V
+20 V
Overload
Offset –10 V
+30 V
Offset +10 V
Offset range
±10 V
–30 V
–20 V
–10 V
0 V
+10 V
+8 V
–8 V
Probes_and_accessories_bro_en_3606-8866-12_v1400.indd 14 23.07.2019 13:47:49