Brochure

Instantaneous power consumption
Voltage at DUT
Current consumption of DUT
Zoom in µA range
12mA
30µA
V
I
V
I
Rohde & Schwarz Probes and accessories for Rohde & Schwarz oscilloscopes 23
Measure up to eight power rails at the same time
with highest accuracy
One R&S®RTE, R&S®RTO or R&S®RTP oscilloscope sup-
ports up to two R&S®RT-ZVC current probes so that it is
possible to observe eight power domains in parallel with
a DC accuracy of 0.1 % for voltage measurements and
0.2 % for current measurements. Ramp-up processes and
power rail tolerances can easily be tested with this probe.
The oscilloscope's SCPI remote control enables automatic
testing.
The R&S®RT-ZVC probe provides an extraordinarily high dynamic range for measuring both active state currents and sleep currents, in this example
12mA and 30µA. Automated measurements make it possible to calculate the total energy consumption.
Digital acquisition system
The R&S®RT-ZVC probe's digital acquisition system provides 18-bit resolution, a
5Msample/s sampling rate and 1MHz bandwidth. Each voltage and current input pair
forms a high dynamic range power measurement system.
High bandwidth with flexible filtering for noise
reduction
A bandwidth of 1 MHz and a sampling rate of
5Msample/s allows you to capture fast current pulses. To
analyze the overall power consumption of battery powered
devices, the very low sleep mode currents have to be cap-
tured at the same time. For very high dynamic range mea-
surements, the integrated lowpass filter reduces the band-
width down to 5 kHz and minimizes overall system noise.
Current ranges
Low-gain mode, shunt
±4.5µA; ±45µA, 10 kΩ
±4.5mA; ±45mA, 10 Ω
±4.5A; ±10A, 10 mΩ
±45mV
1)
; ±450mV
1)
, external
Voltage ranges
±1.88V
±3.75V
±7.5V
±15V
1)
Current range depends on shunt value.
Digital backend (4 in total)
A/D
18 bit
5 Msample/s
A/D
18 bit
5 Msample/s
5 Msample/s
Trigger
Analog frontend
Deskew
Lowpass
Probes_and_accessories_bro_en_3606-8866-12_v1400.indd 23 23.07.2019 13:48:01