Datasheet

Version 20.00, November 2019
Rohde & Schwarz R&S
®
RT-Zxx High Voltage and Current Probes 13
R&S
®
RT-ZI10C
Step response
Rise time
system, 10 % to 90 %
700 ps (meas.)
Frequency response
Bandwidth
system, 3 dB, starting at DC
> 500 MHz (meas.)
Input impedance
DC input resistance
system
10 MΩ ± 1 % (meas.)
Input capacitance
system
11 pF (meas.)
DC characteristics
Attenuation
system
10:1
between probe tip and probe reference terminal
derated, see figure on page 14
300 V (RMS), CAT III
between probe terminals and earth ground
derated, refer to base unit manual
300 V (RMS)
Base unit
Use with
R&S
®
RTH
Input capacitance
must be compensated by probe’s
LF compensation
10 pF to 22 pF
Input coupling
1 MΩ AC/DC