Datasheet
Version 20.00, November 2019
36 Rohde & Schwarz R&S
®
RT-Zxx High Voltage and Current Probes
R&S
®
RT-ZC02/-ZC03 current probes
All parameters are valid when the probe is connected to an appropriate Rohde & Schwarz oscilloscope with an input impedance of 1 MΩ.
See table on page 4 and Rohde & Schwarz oscilloscope operating manual for more details.
R&S
®
RT-ZC02
Sensitivity setting
0.01 V/A
0.001 V/A
Step response
Rise time
10 % to 90 %
20 µs (meas.)
Frequency response
Bandwidth
–3 dB, starting at DC
20 kHz (meas.)
DC characteristics
Dynamic range
derated, see figures on page 39
±200 A
±2000 A
Sensitivity error
+23 °C ±1 °C, ±1500 A
±1 % (meas.)
+23 °C ±1 °C, ±2000 A
±5 % (meas.)
Temperature drift, sensitivity
±0.15 %/°C (meas.)
Zero error
referenced to probe input after
demagnetizing and zero adjustment
±100 mA (meas.)
±500 mA (meas.)
AC characteristics
Maximum slew rate
±20 A/µs (meas.)
Maximum rated input
Maximum continuous current
1000 A (RMS)
Maximum working voltage
for uninsulated conductors
300 V (RMS) CAT III
Other
Noise
with 20 MHz lowpass filter
30 mA (RMS) (meas.)
80 mA (RMS) (meas.)
Base unit
Input coupling
1 MΩ