INSTRUCTION MANUAL RT-ZD002 / RT-ZD003 25 MHz Active Differential Probes RT-ZD002 (1337.9700.02) RT-ZD003 (1337.9800.
These probes are in compliance with IEC-61010-031 CAT III, Pollution Degree 2 1. Safety Terms and Symbols Terms appear in this manual: ___________________________________________________ WARNING. Warning statements identify conditions or practice that could result in injury or loss of life. ___________________________________________________ CAUTION. Caution statements identify conditions or practice that could result in damage to this product or other property.
Must be Grounded This probe is grounded with the shell of BNC connector and an auxiliary grounding terminal, through the grounding conductor of the power cord of the measurement instrument. Before making connections to the input leads of this probe, ensure that the output BNC connector is attached to the BNC connector of the measurement instrument and the measurement instrument is properly grounded.
. Installation a. Simply plug-in the BNC output connector to the vertical input of a general purposed oscilloscope or other measurement instrument. The measurement instrument must be ground referenced. b. Connect an appropriate power source to the probe or enter the batteries, then turn it on. c. Select the proper attenuation ratio. When measuring signals below 70 V or 140 V, switch the attenuation ratio to 1/10 (RT-ZD002) or 1/20 (RT-ZD003) in order to get higher resolution and less noise.
6. Available Power Sources • 4 x AA batteries • USB Power Cord, for oscilloscopes which offer USB connector. The supplied voltage must be less than 12 V and greater than 4.5 V, otherwise the probe could be damaged or can’t be operated properly. Polarity is “+” inside and “–” outside. For wrong polarity a built-in circuit protects the probe, no danger or damage will occur. When the voltage of the cells become too low, the power indicator on the front panel will flicker. 7.
8. Specifications RT-ZD002 RT-ZD003 Bandwidth DC to 25 MHz (-3 dB) DC to 25 MHz (-3 dB) Attenuation Ratio 1:10 / 1:100 1:20 / 1:200 Accuracy ±2 % (meas.) ±2 % (meas.) Rise Time 14 ns (calculated from bandwidth) 14 ns (calculated from bandwidth) Input Impedance 8 MΩ // 2.75 pF differential 4 MΩ // 5.5 pF each side to ground 8 MΩ // 2.75 pF differential 4 MΩ // 5.
9. Derating Curve The derating curve of the absolute maximum input voltage in common mode is shown as follows and valid for both models RT-ZD002 and RT-ZD003. Voltage (V rms) )s m r tl o V ( e ga tl o V 10000 1000 1000 1000 700 150 100 1,0E+06 1,0E+07 1,0E+08 Frequency (Hz) 10. Inspection Procedure a. Connect the BNC output connector to the vertical input of a general purpose oscilloscope. b. Install four AA cells or connect an appropriate power lead. c.
12. WEEE / RoHS Directives This electronic product is subject to disposal and recycling regulations that vary by country and region. Many countries prohibit the disposal of waste electronics equipment in standard waste receptacles. 13. Manufacturer ROHDE & SCHWARZ For comprehensive information about Rohde and Schwarz, please visit our homepage on the R&S Internet (http://www.rohde-schwarz.com). For queries regarding technical aspects of our products, please contact our customer support at http://www.