User Manual

Multimeter Measurements
R&S
®
Scope Rider RTH
144User Manual 1326.1578.02 ─ 08
b) Adjust the "Probe Setting" for all measured channels.
See also "Probe Setting" on page 39.
2. If the 4-voltmeter-view is shown, switch to the one-voltmeter-view.
See "Displaying voltmeters" on page 143.
3. Select the channel to be measured (no. 8 in Figure 6-3).
4. Select the measurement type (no. 10).
5. Activate the voltmeter (no. 13)
6. To adjust the measurement range manually, press the RANGE keys.
7. If you want to get relative result values:
a) Activate "Relative" (no. 12).
b) To set a user-defined reference value, open the "Meter" menu.
c) Activate "Reference", and enter the reference value in "Reference Manual".
8. To stop the meter measurement, press the RUN STOP key.
The status "Hold" is displayed on the upper left. Stopping the measurement does
not delete statistical values. The measurement continues when you press RUN
STOP again.
Alternatively, you can select the voltmeter and adjust the meter settings in the "Meter"
menu.
6.2.4 Voltmeter Settings
Access: "Meter" menu
Voltmeter (R&S RTH1004)