User Manual

Remote Control Commands
R&S
®
Scope Rider RTH
273User Manual 1326.1578.02 ─ 08
See TRIGger:PATTern:WIDTh:RANGe on page 272.
Parameters:
<Duration> Range: 800E-12 to 10000
Increment: 100E-9
*RST: 5E-9
Default unit: s
TRIGger:PATTern:WIDTh:DELTa <Tolerance>
Sets a range Δt to the pattern width that is defined by TRIGger:PATTern:WIDTh[:
WIDTh].
Parameters:
<Tolerance> Range: 0 to 5000
Increment: 500E-12
*RST: 0
Default unit: s
TRIGger:PATTern:WIDTh:MINWidth <MinDuration>
Sets the lower time limit of the pattern match for range conditions WITHin and OUT-
Side.
Parameters:
<MinDuration> Range: 800E-12 to 10000
Increment: 100E-9
*RST: 5E-9
Default unit: s
TRIGger:PATTern:WIDTh:MAXWidth <MaxDuration>
Sets the upper time limit of the pattern match for range conditions WITHin and OUT-
Side.
Parameters:
<MaxDuration> Range: 800E-12 to 10000
Increment: 100E-9
*RST: 5E-9
Default unit: s
14.3.5.8 State Trigger (R&S RTH-K19)
See also Chapter 2.5.8, "State Trigger (R&S RTH-K19)", on page 60.
TRIGger:STATe:CHANnel<m>........................................................................................274
TRIGger:STATe:COMBination.........................................................................................274
TRIGger:STATe:CSOurce[:VALue].................................................................................. 274
TRIGger:STATe:CSOurce:EDGE.....................................................................................274
Waveform Setup