User Manual
Remote Control Commands
R&S
®
Scope Rider RTH
294User Manual 1326.1578.02 ─ 08
Suffix:
<m>
.
1..2
Defines the measurement index. Two simultaneous cursor mea-
surements can be performed.
Return values:
<ResultLimit> INSide | OVERflow | UNDerflow | OVUNflow
*RST: INSide
Usage: Query only
14.4.4 Math Waveforms
14.4.4.1 Math Settings
CALCulate:MATH:STATe................................................................................................294
CALCulate:MATH[:EXPRession][:DEFine]........................................................................ 294
CALCulate:MATH:VERTical:SCALe.................................................................................295
CALCulate:MATH:VERTical:RANGe................................................................................ 295
CALCulate:MATH:VERTical:POSition.............................................................................. 295
CALCulate:MATH:STATe <State>
Enables or disables the math channel.
Parameters:
<State> ON | OFF
Usage: SCPI confirmed
CALCulate:MATH[:EXPRession][:DEFine] <ExprDefinition>
Sets the operation to calculate a math waveform.
Parameters:
<ExprDefinition> String that defines the operation. x is the channel number of
source 1, y the channel number of source 2.
Addition: 'Cx+Cy'
Subtraction: 'Cx-Cy'
Multiplication: 'Cx*Cy'
Inverse: '-Cx'
Absolute value: 'Abs(Cx)'
Square: 'Pow(Cx)'
Example:
CALC:MATH:EXPR:DEF 'C1-C2'
Subtracts the values of CH2 from the values of CH1.
CALC:MATH:EXPR:DEF 'Pow(C1)'
Squares the values of CH1.
Usage: SCPI confirmed
Waveform Analysis